Brochure

Table Of Contents
Curve charts and technical data
UP, UPS Series 200
9
54
UPS 80-40/4, 3 ph, 208-230 V, 460 V, 575 V
, 60 Hz
Note: ETA is calculated as wire-to-water efficiency.
Dimensions
Product numbers Connections
Electrical data
TM00 9506 0307
Flow range: 30 - 200 gpm
Head range: 1 - 13 ft
Motor: 4-pole 0.5 Hp
Max. liquid temp (Open): +140 °F
Max. liquid temp.: +248 °F
Min. liquid temp.: +32 °F
Max. system pressure: 145 psi
Net wt: 78.7 lbs (35.7 kg)
Gross wt.: 9.1 lbs (41.3 kg)
Shipping volume: 2.90 ft
3
(0.082 m
3
)
Net wt. bronze: 91.9 lbs (41.7 kg)
Gross wt. bronze: 104.3 lbs (47.3 kg)
Shipping volume bronze: 2.90 ft
3
(0.082 m
3
)
0 40 80 120 160 200 Q [US GPM]
0
2
4
6
8
10
12
14
16
H [ft]
0
1
2
3
4
H [m]
0 10 20 30 40
Q [m³/h]
1
2
3
0 40 80 120 160 200 Q [US GPM]
0
200
400
600
P1 [W]
0
20
40
60
Eta [%]
0.0
0.2
0.4
0.6
0.8
P1 [hp]
3
2
1
Eta
TM02 0730 5100
B2
NPT 1/4
B1
H2
H1
H3
M
D5
D4
D3
D1
B7
B4
B5
L1
L3
D2
D6
D7
Model L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 M
UPS 80-80/4
[in] 19.00 9.50 5.75 6.68 4.94 3.94 6.31 3.81 11.25 15.15 3.19 5.00 6.00 7.56 0.75
[mm] 483 241 146 170 125 100 160 97 286 385 81 127 152 192 19 M16
Model type
Product number
Voltage
[V]
Cast Iron Bronze
UPS 80-40/4
(3 ph)
96402894 96402899 208-230
96402895 96402900 460
96402896 96402901 575
Flange size Flange type
3" ANSI 125# R.F. GF80
Speed
Max amps
[A]
P Max
[Watts]
Start amps
[A]
All 3-phase, 460V and 575V pumps are 2-speed only.
Canada only.
208-230V 460V 575V 208-230V 460V 575V
3 1.62 0.81 0.65 380 7.10 3.50 2.80
2 0.87 0.44 0.35 260 3.81 1.90 1.52
10.77▲▲230 3.37 ▲▲
UPS 80-40/4
3 ph, 208-230 V, 460 V, 575 V
, 60 Hz