Brochure
SERIES II
EF
APPLICATIONS
• Graywater pumping
• Septic Tanks Effluent
• STEP Systems
• Water transfer
• Dewatering
• Basement Sumps
SPECIFICATIONS
• 1/4 hp, 115 volt, 1-phase
• Capacity to 29 GPM
• Heads to 17 feet
• Discharge size 1-1/4” female
NPT and 3/4” adjustable
hose fitting (included)
• Power Cord 8’
• Solids 1/4” convertible to
1/2” maximum
MATERIALS OF
CONSTRUCTION
Engineered Composite
FEATURES & BENEFITS
• Lightweight
• Corrosion resistant
• Manual or automatic
operation
• Swing or vertical float
option
• Impact resistant
• Continuous duty
when fully submerged
• Fluid Temp. Range:
40°F (0°C) min.
120°F (48.9°C) max.
AGENCY LISTINGS
UL Listed
Canadian Standard
Association
APPLICATIONS
• Graywater pumping
• Septic Tanks Effluent
• STEP Systems
• Water transfer
• Basement Sumps
PUMP MODELS
EF302
• 3/10 hp, 115 volt, 1-phase
EF332
• 1/3 hp, 115 volt, 1-phase
EF402
• 4/10 hp, 115 volt, 1-phase
SPECIFICATIONS
• Capacity to 59 GPM
• Heads to 31 feet
• Discharge size 1-1/2”
female NPT
• Power Cord 10’ or 20’
• Solids 1/2” maximum
(EF302)
• Solids 3/4” maximum
(EF332 & EF402)
MATERIALS OF
CONSTRUCTION
Stainless Steel
Engineered Composite
FEATURES & BENEFITS
• Lightweight
• Corrosion resistant
• Manual or automatic
operation
• Swing or vertical float option
• Field replaceable power cords
• Continuous duty when fully
submerged
• Fluid Temp. Range:
32°F (0°C) min.
104°F (40°C) max.
AGENCY LISTINGS
UL Listed
UL Listed to Canadian
safety standards
18
16
14
12
10
8
6
4
2
0
0 5 10 15 20 25 30
HEAD (FEET)
PERFORMANCE
PERFORMANC
E
U.S. GALLONS PER MINUTE
EF25
EF25
35
30
25
20
15
10
5
0
0 40 45 50 55 60 65105 15 20 25 30 35
HEAD (FEET)
U.S. GALLONS PER MINUTE
PERFORMANCE
PERFORMANC
E
EF302
EF302
EF402
EF402
EF332
EF332
EF25
EF
TDH 25
2 26
4 23.5
6 20.5
8 17.5
10 14
12 10.5
14 6.5
GRUNDFOS EFFLUENT PUMPS
EF EF EF
TDH 302 332 402
5 38 45 52
10 31 36 44
15 22 26 34
20 11 15.5 23
25 12
PERFORMANCE
IN GALLONS
PER MINUTE
PERFORMANCE
IN GALLONS
PER MINUTE