Submittal Sheet
Table Of Contents
- 1. Product overview, Unilift
- 2. General data, Unilift
- 3. Technical data and performance curves
- 4. Control panels
- 5. Alarms
- 6. Accessories
- 7. Pump and system sizing instructions
- 8. Grundfos Product Center
General data, Unilift
Unilift CC, KP, AP
2
5
Applications
The Unilift CC, KP and AP are submersible wastewater
pumps suitable for temporary as well as permanent
free-standing installation.
The pumps are designed for intermittent operation.
pH values:
Maximum density: 146.88 ounce/gallon.
Maximum installation depth below water level: 34 feet.
Examples of applications
Wastewater definitions
Drainage
Raw water, drainage and untreated wastewater
containing solids no larger than 0.4" from households,
farms and small industry.
Effluent
Dirty water and untreated wastewater (excluding toilet
discharge), containing fibers and solids no larger than
1.4" from dewatering systems, domestic wastewater
systems and small industry.
Sewage
Untreated wastewater and raw sewage containing
fibers, textiles and other solids, including toilet
discharge from domestic sewage systems, farms and
industry no larger than 2.0".
Pump overview
• Unilift CC: 4 to 9
• Unilift KP: 4 to 9
• Unilift AP: 4 to 10.
Application
Unilift pump type
CC KP AP12 AP35 AP35B AP50 AP50B
Max. liquid temperature 104 °F 122 °F 131 °F 131 °F 104 °F 131 °F 104 °F
Max. particle size [mm] / [inch] 10/0.4 10/0.4 12/0.4 35/1.4 35/1.4 50/2.0 50/2.0
Non-permanent, light-duty applications (used as a portable pump) ●●
Non-permanent, heavy-duty applications for installers and light industry
(used as a portable pump)
●●●●●
Pumping of:
Water and rainwater in horticulture ●●●
Water from rivers and lakes ●●●●●●●
Rainwater, drainage water and water from flooding ●●●●●●●
Water for filling/emptying containers, ponds, tanks, etc. ●●●●●●●
Effluents from showers, washing machines and sinks below sewer level ●●●●●●●
Pool water ●●●●●●●
Ditch drainage water ●●●●●●●
Groundwater (lowering applications) ●●●●●●●
Domestic effluents from septic and sludge-treating systems ●●●●●●
Liquids containing fibres from light industry, laundries, etc. ●●●●
Effluents from viaducts, underpasses, etc. ●●●●
Drainage water from garage sprinkler systems
Domestic wastewater with toilet discharge from pipes and water closets
below sewer level, outdoor pump installations
●●
Domestic wastewater with toilet discharge from pipes and water closets
below sewer level, indoor pump installations
Not applicable
= Recommended pump type
= Alternative pump type
Pump range
Unilift
Free passage
[mm] / [inch]
Impeller type
Number of
motor poles
CC 10/0.4 Semi-open 2
KP 10/0.4 Semi-open 2
AP12 12/0.4 Semi-open 2
AP35 35/1.4 Vortex 2
AP35B 35/1.4 Vortex 2
AP50 50/2.0 Vortex 2
AP50B 50/2.0 Vortex 2