Submittal Sheet

Table Of Contents
Technical data and performance curves
Unilift CC, KP, AP
3
34
Technical data
With float switch
Fig. 25 Minimum well dimensions AP50
If the pump is installed in a collecting well, the
minimum dimensions of the well should be as shown
above to ensure free movability of the float switch.
Without float switch
Fig. 26 Pump dimensions
The space required corresponds to the physical
dimensions of the pump.
Product no. Pump type
Voltage
[V]
P2
[hp]
I
n
[A]
I
Start
[A]
Dimensions [inches]
Weight
[lbs]
Cable length and plug
ABS
96010686 AP50.50.08..1.V 1 x 230 1.0 6.3 29 17.17 9.49 2 NPT 35.3 10 feet / No Plug
96010689 AP50.50.08.1.V 1 x 230 1.0 6.3 29 17.17 9.49 2 NPT 35.3 25 feet / No Plug
96847180 AP50.50.08.A.1.V 1 x 230 1.0 6.3 29 17.17 9.49 2 NPT 35.3 10 feet / No Plug
96847181 AP50.50.08.A.1.V 1 x 230 1.0 6.3 29 17.17 9.49 2 NPT 37.3 25 feet / No Plug
96010692 AP50.50.11.1V 1 x 230 1 1/2 8.4 35 17.17 9.49 2 NPT 35.3 10 feet / No Plug
96010695 AP50.50.11.1V 1 x 230 1 1/2 8.4 35 17.17 9.49 2 NPT 35.3 25 feet / No Plug
96847182 AP50.50.11.A.1V 1 x 230 1 1/2 8.4 35 17.17 9.49 2 NPT 37.0 10 feet / No Plug
96847183 AP50.50.11.A.1V 1 x 230 1 1/2 8.4 35 17.17 9.49 2 NPT 37.3 25 feet / No Plug
TM04 3263 4009
‹‹
‹‹
23.5"
21.5
Well dimensions with float switch
TM00 5524 0995
S
B
A