Technical data and performance curves
Unilift CC, KP, AP
3
26
Motor cable
The motor is a single- or three-phase asynchronous
dry-rotor motor.
Enclosure class: IP68
Insulation class: F (311 °F)
Cable type: SJOW-A.
Single-phase motors have built-in thermal protection.
Adjustment of cable length for float
switch
The difference in level between start and stop can be
adjusted by changing the free cable length between
the float switch and the pump handle.
• Increasing the free cable length will result in fewer
starts/stops and a large difference in level.
• Reducing the free cable length will result in more
frequent starts/stops and a small difference in level.
In order for the float switch to start and stop the pump,
the free cable length must be min. 4". When adjusting
the free cable end, make sure that the pump housing is
always covered by water.
Intermittent operation
Pumps with float switch are suitable for intermittent
operation.
The pump is allowed to run for maximum 5 minutes per
30 minutes without the motor being submerged in the
liquid.
Continuous operation
During continuous operation, the pump must always
be completely covered by the pumped liquid.
Materials
Component Material DIN W.-Nr. AISI
Pump housing Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Washer Stainless steel 1.4301 304
Protective cap Novolen 2360 Kx
Motor unit complete
Parts in contact with
liquid: Stainless steel
1.4401 316
Pump shaft - wet end Stainless steel 1.4301 304
Motor cable Neoprene
O-rings NBR rubber
Spring Stainless steel 1.4310
Pump inlet Stainless steel 1.4301 304
Ring stand Polycarbonate
Oil Shell Ondina 15, non-toxic