Submittal Sheet

Table Of Contents
Technical data and performance curves
Unilift CC, KP, AP
3
21
Motor cable
The motor is a single- or three-phase asynchronous
dry-rotor motor.
Enclosure class: IP68
Insulation class: F (311 °F)
Cable typea: SJOW-A.
Single-phase motors have built-in thermal protection.
Adjustment of cable length for float
switch
The difference in level between start and stop can be
adjusted by changing the free cable length between
the float switch and the pump handle.
Increasing the free cable length will result in fewer
starts/stops and a large difference in level.
Reducing the free cable length will result in more
frequent starts/stops and a small difference in level.
In order for the float switch to start and stop the pump,
the free cable length must be min. 4". When adjusting
the free cable end, make sure that the suction strainer
is always covered by water.
Materials
Component Materials DIN W.-Nr. AISI
Pump housing Stainless steel 1.4301 304
Riser pipe Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Pump sleeve Stainless steel 1.4401 316
Pump shaft - wet end Stainless steel 1.4301 304
Bearings Heavy-duty prelubricated ball bearings
O-rings NBR rubber
Screws Stainless steel 1.4301 304
Cables Neoprene
Oil Shell Ondina 15, non-toxic