SQFlex Service Instructions
24 / 60
3.2 Wind turbine
Monthly maintenance
Test brake
(This checks electrical wiring.)
Stop the wind turbine in a moderate wind (charging 
but not furling). No unusual difficulty or noise 
should be experienced in stopping the propeller. A 
noise during braking can indicate a disconnected 
wire.
Check mechanical condition
Watch and listen from the tower base.
Use binoculars. The propeller and tail must not 
wobble. There should be no mechanical noise, rat-
tle or vibration. 
Lower or climb the tower for inspection, if required. 
There should be no buzzing either heard or felt 
with your hand on the tower mast. Go to section
 Electrical problems on page 21
, if required.
Inspect the tower
Follow all inspection and maintenance require-
ments of the tower manufacturer. Tighten all nuts 
and screws, especially wire clips. Check for cracks 
and bent or broken parts at the anchors and base 
structure. Check for broken wire strands and 
tighten guys.
Annual maintenance
Complete mechanical check
• Lower the tower
• Repair or replace any worn or loose parts.
• Check tightness of all tower mounting nuts and 
screws and propeller mounting screws.
• Check all bearings. Just perceptible play is 
acceptable.
• Clean the propeller with mild detergent to 
remove all dirt and debris. Replace blades if 
they are cracked or damaged.
Tighten tower, 
tail, hub and 
blade mounting 
screws.
Do not tighten 
pivot pin nut.
sqflex_SI_US_WG.book Page 24 Thursday, October 1, 2009 3:27 PM