UPSeries.
UPSeries.
UPSeries.
UPSeries.
UPSeries.book Page 5 Monday, March 21, 2011 8:54 PM Cross reference UP Series Reference for replacing ALPHA models Competitor cross-reference Model ALPHA 15-55 F/SF Speed TACO* Bell & Gossett* Armstrong* High 005F, 007F, 008F, 0010F-IFC,00R-MSF1-IFC NRF-22, LR-20WR Astro 30, Astro 50-3 Med.
UPSeries.book Page 6 Monday, March 21, 2011 8:54 PM Cross reference UP Series Reference for replacing TACO models Competitor cross-reference Open systems: Stainless steel and bronze body pumps Comparable Grundfos replacement options Primary model (s) Page no. Conn.
UPSeries.
UPSeries.book Page 8 Monday, March 21, 2011 8:54 PM Cross reference UP Series Reference for replacing Bell & Gossett models Competitor cross-reference Open systems: Stainless steel and bronze body pumps Grundfos Primary model(s) UP 15-10 B5 Bell & Gossett* Page Conn. type 30 1/2" sweat Pump length Model [inches] 5 5 7/8 Conn.
UPSeries.book Page 9 Monday, March 21, 2011 8:54 PM Cross reference UP Series Reference for replacing Laing models Competitor cross-reference Open systems: Stainless steel and bronze body pumps Comparable Grundfos replacement options Model(s) Page Laing pumps* Conn.
UPSeries.book Page 10 Monday, March 21, 2011 8:54 PM Cross reference UP Series Reference for replacing Armstrong models Competitor cross-reference Open systems: Stainless steel and bronze body pumps Comparable Grundfos replacement options Primary model(s) Armstrong pumps* Pump length [inches] Conn. type Pump length Astro 20B050S 1/2" sweat 5 Astro 20B050S-LC 1/2" sweat 5 Page Conn.
UPSeries.book Page 11 Monday, March 21, 2011 8:54 PM Cross reference UP Series Discontinued products The table shows which new products replace discontinued products.
UPSeries.
UPSeries.book Page 13 Monday, March 21, 2011 8:54 PM Performance ranges UP Series 3-speed stainless steel H UPS [ft] 18 60 Hz 16 14 UPS 15-55 12 10 8 6 UPS 15-35 4 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Q [US GPM] TM04 5462 2 Comfort Pump H [ft] a. a. UP10-65B5 UP 10-16 B5 b. b. UP10-16BN5 UP 10-16 BN5 5.0 b 4.5 4.0 a 3.5 3.0 2.5 2.0 1.5 0.5 0.0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 Q [GPM] TM03 8851 2807 1.0 Note: a. UP 10-16 B5 b.
UPSeries.book Page 14 Monday, March 21, 2011 8:54 PM Performance ranges UP Series Closed systems H [ft] 36 1. 2. 3. 4. 5. 6. 7. 8. 9. 1 32 2 28 4 24 UP 26-116 F UP 26-99 F UP 43-75 F UP 26-96 F UP 26-64 F UP 15-42 F UP 15-10 F/FR UP 15-100 F UP 26-120 U 5 20 3 8 16 6 12 8 0 0 4 8 12 16 20 24 28 32 36 40 44 Q [US GPM] TM03 9128 3407 9 7 4 Open systems H [ft] 32 10. UP 26-99 BF 11. UP 43-75 BF 12. UP 26-96 BF 13. UPS 15-55 SU/SF 14. UPS 15-35 SU/SF 15. UP 15-29 SU/SF 16.
UPSeries.book Page 15 Monday, March 21, 2011 8:54 PM Performance ranges UP Series Open systems 1/2" H [ft] 1. UP 15-42 B5 2. UP 15-18 B5 3. UP 15-10 B5 4. UP 15-42 BUC5 5. UP 15-18 BUC5 6. UP 15-10 BUC5 4 15 14 13 12 11 10 9 8 1 7 6 5 5 4 2 3 3 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 Q [US GPM] TM03 9131 3507 6 2 Open systems 3/4" H [ft] 7. UP 15-42 B7 8. UP 15-18 B7 9. UP 15-10 B7 10. UP 15-42 BUC7 11. UP 15-18 BUC7 12.
UPSeries.
UPSeries.
UPSeries.
UPSeries.
UPSeries.book Page 20 Monday, March 21, 2011 8:54 PM Identification UP Series Nameplate NONSUBMERSIBLE CIRCULATION PUMP Type UP 15 - 42F P/N: 59896155 115 V 1PH PC: 0452 P1 60Hz US 10uF Class F IMPEDANCE PROTECTED I1/1 (A) P1 (W) .74 85 - FOR INDOOR USE ONLY MAX FLUID TEMP. 230F 99K4 C UL US LISTED NONSUBMERSIBLE CIRCULATION PUMP Type UP 15 - 42F P/N: 59896155 115 V 1PH PC: 0452 P1 60Hz US 10uF Class F IMPEDANCE PROTECTED I1/1 (A) P1 (W) .74 85 - FOR INDOOR USE ONLY MAX FLUID TEMP.
UPSeries.book Page 21 Monday, March 21, 2011 8:54 PM Applications UP Series The Grundfos circulator pumps, Series UP(S), are specifically designed for heating systems. The pumps are also suitable for circulation of hot domestic water and for circulation of liquid in cooling and airconditioning systems.
UPSeries.book Page 22 Monday, March 21, 2011 8:54 PM Applications Materials of construction Installation Description (UP closed systems) The pump must always be installed with horizontal motor shaft.
UPSeries.book Page 23 Monday, March 21, 2011 8:54 PM Applications UP Series Pumped liquids The ambient temperature for standard pumps with a permissible liquid temperature from 36 °F (2 °C) to 230 °F (110 °C) should always be lower than the liquid temperature, as otherwise condensation may form in the stator housing.
UPSeries.book Page 24 Monday, March 21, 2011 8:54 PM Applications ALPHA UP Series Control display The Grundfos Alpha is the next generation of energy efficient wet-rotor circulators. By incorporating a permanent magnet motor design, power consumption is now reduced by a minimum of 50 %. By using the AutoADAPT™ feature, Grundfos ALPHA will automatically analyze the system demands and adjust head and or flow requirements to meet changing heating demands.
UPSeries.book Page 25 Monday, March 21, 2011 8:54 PM Applications UP Series The Grundfos MixiMizer, a fully integrated injection pump and indoor/outdoor controller, is the only pump and controller system of its kind. Equipped with a weather responsive control, also known as indoor/outdoor control or reset control, the MixiMizer automatically calculates and controls mixed water temperatures according to outdoor temperatures in primary/secondary piping systems.
UPSeries.book Page 26 Monday, March 21, 2011 8:54 PM Applications UP Series Variable-speed pump H [ft] 32 dd 28 If desired, the manual-% dial allows the speed of the pump to be manually adjusted and set by the user. The speed of the pump may be manually adjusted anywhere from min. to 100 %, but once set, remains fixed at that speed.
UPSeries.book Page 27 Monday, March 21, 2011 8:54 PM Applications UP Series Comfort System The Comfort System uses a patented Comfort Valve® and pump to provide instant availability of hot water at the point of use. Operation The Comfort Valve® is installed at the furthest fixture from the hot-water tank. With a built-in timer, the pump allows hot water to circulate along the loop through the valve using the cold-water side as a return line.
UPSeries.book Page 28 Monday, March 21, 2011 8:54 PM Applications UP Series UP 10 Comfort pump The water-conduction part of the pump is hermetically separated from the stator with a stainless steel spherical separator. The motor can be separated from the pump housing, enabling easy maintenance and replacement.
UPSeries.book Page 29 Monday, March 21, 2011 8:54 PM Technical data UP 10-16 B5/BN5 UP 10 Comfort Pump H [ft] UP10-16B5 a.a.UP 10-16 B5 UP10-16BN5 b.b.UP 10-16 BN5 5.0 bb 4.5 4.0 aa Flow range: 0-3.5 gpm Head range: 0-5.4 feet Motors: Single-phase Max. liquid temperature: 203 °F (95 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 3.5 Model 3.0 Volts Amps Watts Hp Capacitor 115 0.23 25 - - UP 10-16 B5/BN5 2.5 Approvals 2.0 1.5 0.5 0.0 0.
UPSeries.book Page 30 Monday, March 21, 2011 8:54 PM Technical data UP 15-10 B5/B7 H [ft] a. a. UP UP 15-10B5 15-10 B5 b. UP UP 15-10B7 15-10 B7 b. 7 b 6 b aa 5 Flow range: 0-8.2 gpm Head range: 0-6.2 feet Motors: 2-pole, single-phase Max. liquid temperature: 220 °F (104 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C).
UPSeries.book Page 31 Monday, March 21, 2011 8:54 PM Technical data H [ft] UP 15-10 BUC5/7 a 6.5 a a. UP UP 15-10 15-10BUC5 BUC5 b. UP BUC7 b. UP 15-10 15-10BUC7 6.0 5.5 bb 5.0 Flow range: 0-6.6 gpm Head range: 0-6.6 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 4.5 Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 4.0 3.
UPSeries.book Page 32 Monday, March 21, 2011 8:54 PM Technical data UP 15-10 F/FR H [ft] 6 5 Flow range: 0-8.0 gpm Head range: 0-5.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Closed system 4 Model 3 UP 15-10 F/FR Volts Amps Watts Hp Capacitor 115 0.
UPSeries.book Page 33 Monday, March 21, 2011 8:54 PM Technical data UP 15-10 SU7P/TLC UP Comfort System H [ft] 5.0 4.5 4.0 Flow range: 0-6.3 gpm Head range: 0-5.1 feet Motors: 2-pole, single-phase Max. liquid temperature: 150 °F (66 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Open system 3.5 Model 3.0 UP 15-10 SU7P/TLC Volts Amps Watts Hp Capacitor 115 0.23 25 1/25 2μF/400 V 2.5 Approvals 2.0 1.5 1.0 TM03 5547 3806 0.5 0.0 0.0 0.5 1.
UPSeries.book Page 34 Monday, March 21, 2011 8:54 PM Technical data UP 15-18 B5/B7 H [ft] 14 a. UP UP15-18 15-18B5 a. B5 b. B7 b. UP UP15-18 15-18B7 13 12 11 10 9 Flow range: 0-14.7 gpm Head range: 0-13.9 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C).
UPSeries.book Page 35 Monday, March 21, 2011 8:54 PM Technical data UP 15-18 BUC5/BUC7 H [ft] a. UP UP15-18 15-18BUC5 a. BUC5 UP15-18 15-18BUC7 b. UP BUC7 16 bb 14 aa 12 Flow range: 0-14.7 gpm Head range: 0-14.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 10 Model Volts Amps Watts Hp Capacitor UP 15-18 BUC5 115 0.55 60 1/25 8μF/180 V UP 15-18 BUC7 115 0.
UPSeries.book Page 36 Monday, March 21, 2011 8:54 PM Technical data UP 15-29 SU/SF H [ft] 10 Flow range: 0-20.5 gpm Head range: 0-9.7 feet Motors: 2-pole, single-phase 9 Max. liquid temperature: 230 °F (110 °C) and 150 °F 8 Min. liquid temperature: 36 °F (2 °C) 7 Max. system pressure: 6 Open system 145 psi (10 bar) Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 5 4 Model Volts Amps Watts Hp 0.75 87 0.12 0.75 87 0.12 0.
UPSeries.book Page 37 Monday, March 21, 2011 8:54 PM Technical data UP 15-35 SUC H [ft] 12 10 8 Flow range: 0-17.5 gpm Head range: 0-11.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Open system 6 Model UP 15-35 SUC 4 Volts Amps Watts Hp Capacitor 230 0.42 114 0.
UPSeries.book Page 38 Monday, March 21, 2011 8:54 PM Technical data UPS 15-35 SUC/SFC H [ft] 12 33 Flow range: 0-21.5 gpm Head range: 0-12 feet Motors: 2-pole, single-phase 11 Max. liquid temperature: 165 °F (74 °C) 10 Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 9 8 Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C).
UPSeries.book Page 39 Monday, March 21, 2011 8:54 PM Technical data UP 15-42 B5/B7 H [ft] a. UP 15-42 B5 a. 15-42B5 b. UP UP 15-42 B7 b. 15-42B7 16 b 14 a 12 Flow range: 0-17 gpm Head range: 0-15 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C).
UPSeries.book Page 40 Monday, March 21, 2011 8:54 PM Technical data UP 15-42 BUC5/BUC7 H [ft] a. UP UP 15-42 15-42BUC5 BUC5 BUC7 b. UP UP 15-42 15-42BUC7 16 14 Flow range: 0-17 gpm Head range: 0-15 feet Motors: 2-pole, single-phase Max. liquid temperature: 205 °F (96 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 12 10 Model Volts Amps Watts Hp Capacitor UP 15-42 BUC5 115 0.74 85 1/25 10μF/180 V UP 15-42 BUC7 115 0.
UPSeries.book Page 41 Monday, March 21, 2011 8:54 PM Technical data UP 15-42 BUC5/MR and BUC7/MR UP 15 MixiMizer H [ft] a. MINa. MIN -both both models models b. UP 15-42 BUC5 b. MAX - UP15-42BUC5 c. - UP 15-42 BUC 7 c. MAX UP15-42BUC7 16 c Flow range: 0-13.5 gpm Head range: 0-15 feet Motors: 2-pole, single-phase Max. liquid temperature: 205 °F (96 °C) Min. liquid temperature: 36 °F (2 °C) Max.
UPSeries.book Page 42 Monday, March 21, 2011 8:54 PM Technical data UP 15-42 F/FR H [ft] 16 14 Flow range: 0-17 gpm Head range: 0-15 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 12 10 Closed system 8 Model 6 Volts Amps Watts Hp Capacitor 115 0.74 85 1/25 10μF/180 V 230 0.
UPSeries.book Page 43 Monday, March 21, 2011 8:54 PM Technical data UPS 15-42 F H [ft] 16 3 3 14 2 2 12 Flow range: 0-17.5 gpm Head range: 0-15.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 10 Model Spd Volts Amps Watts 0.41 92 0.19 40 0.
UPSeries.book Page 44 Monday, March 21, 2011 8:54 PM Technical data UP 15-42 FC/MR UP 15 MixiMizer H [ft] a. MIN b. MAX 16 b 14 Flow range: 0-16 gpm Head range: 0-15 feet Motors: 2-pole, single-phase Max. liquid temperature: 205 °F (96 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 12 Model Volts Amps Watts Hp Capacitor 115 0.
UPSeries.book Page 45 Monday, March 21, 2011 8:54 PM Technical data UP 15-42 F/VS UP 15 Variable Speed H [ft] a. MIN b. MAX 16 bb 14 Flow range: 0-16 gpm Head range: 0-15.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 205 °F (96 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 12 Model Volts Amps Watts Hp Capacitor 115 0.
UPSeries.book Page 46 Monday, March 21, 2011 8:54 PM Technical data UP 15-55 SUC H [ft] Flow range: 0-21.5 gpm Head range: 0-17 feet 18 Motors: 2-pole, single-phase 16 Max. liquid temperature: 230 °F (110 °C) 14 Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 12 Closed system 10 Model 8 UP 15-55 SUC 6 Volts Amps Watts Hp Capacitor 230 0.42 97 0.
UPSeries.book Page 47 Monday, March 21, 2011 8:54 PM Technical data UPS 15-55 SFC/SUC H [ft] 18 3 16 2 2 14 Flow range: 0-25 gpm Head range: 0-18 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 12 10 11 Model Spd Volts 3 8 UPS 15-55 SFC 115 2 Amps Watts Hp 0.75 87 0.12 0.
UPSeries.book Page 48 Monday, March 21, 2011 8:54 PM Technical data ALPHA 15-55 F/FR/SF/LC UP 15 ALPHA TM04 6025 0611 Performance* and operation mode selection Pos. Description Pos. Description • Push-button for selection of pump setting • Every time the push-button is pressed, the circulator setting is changed Constant Pressure I • The duty point of the pump will move left and right along the lowest constant-pressure curve depending on water demand in the system.
UPSeries.book Page 49 Monday, March 21, 2011 8:54 PM Technical data ALPHA 15-55 F/FR/SF/LC UP 15 ALPHA Flow range: 0-21.5 gpm Head range: 0-17 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 150 psi (10 bar) Closed (F, FR) and Open systems (SF) ALPHA 15-55 F Linecord F B E G A C Model ALPHA 15-55 Volts Amps Watts Hp Capacitor 115 0.65 5 to 45 0.
UPSeries.book Page 50 Monday, March 21, 2011 8:54 PM Technical data UPS 15-58 FC/FRC H [ft] 20 3 18 2 2 16 14 11 12 10 Flow range: 0-17 gpm Head range: 0-19.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Model Spd 8 3 6 UPS 15-58 FC/FRC 4 2 0 0 2 4 6 8 10 12 14 16 18 20 Q [GPM] Watts Hp Capacitor 0.75 87 1/25 0.66 80 1/25 10μF/180 V 0.
UPSeries.book Page 51 Monday, March 21, 2011 8:54 PM Technical data UP 15-100 F Flow range: 0-8.4 gpm Head range: 0-36 feet 36 Motors: 2-pole, single-phase 32 Max. liquid temperature: 205 °F (96 °C) 28 Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) H [ft] 24 Closed system 20 Model 16 UP 15-100 F 12 8 Volts Amps Watts Hp Capacitor 115 1.
UPSeries.book Page 52 Monday, March 21, 2011 8:54 PM Technical data UP 26-64 F Flow range: 0-32 gpm Head range: 0-24.5 feet Motors: 2-pole, single-phase 22 Max. liquid temperature: 230 °F (110 °C) 20 Min. liquid temperature: 36 °F (2 °C) 18 Max. system pressure: 145 psi (10 bar) 16 Closed system H [ft] 26 24 14 12 Model Volts Amps Watts Hp Capacitor 115 1.7 185 1/12 8μF/180 V 230 0.8 175 1/12 2.
UPSeries.book Page 53 Monday, March 21, 2011 8:54 PM Technical data UP 26-64 F/VS UP 26 Variable Speed H [ft] a. MIN MIN b. MAX b. MAX b 24 20 16 Flow range: 0-34 gpm Head range: 0-24.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 195 °F (91 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Model 12 UP 26-64 F/VS Volts Amps Watts Hp Capacitor 115 1.
UPSeries.book Page 54 Monday, March 21, 2011 8:54 PM Technical data UP 26-96 F/BF Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) 26 Max. system pressure: 145 psi (10 bar) 24 Closed system (F) and open system (BF) H [ft] 30 28 22 20 Model Volts Amps Watts Hp Capacitor 115 1.7 205 1/12 10μF/180 V 230 0.8 205 1/12 2.
UPSeries.book Page 55 Monday, March 21, 2011 8:54 PM Technical data UP 26-96 F/VS UP 26 Variable Speed H [ft] a. a. MIN MIN b. b. MAX MAX 32 b 28 Flow range: 0-28 gpm Head range: 0-30 feet Motors: 2-pole, single-phase Max. liquid temperature: 195 °F (91 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 24 20 Model 16 UP 26-96 F/VS Volts Amps Watts Hp Capacitor 115 1.
UPSeries.book Page 56 Monday, March 21, 2011 8:54 PM Technical data UP 26-99 F/BF Flow range: 0-34 gpm Head range: 0-32 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Closed system (F) and Open system (BF) H [ft] 32 28 24 20 Model 16 Volts Amps Watts Hp Capacitor 115 2.15 245 1/6 10μF/180 V 230 1.07 245 1/6 2.
UPSeries.book Page 57 Monday, March 21, 2011 8:54 PM Technical data UPS 26-99 F/BFC H [ft] 33 28 22 24 11 20 Flow range: 0-33 gpm Head range: 0-29 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 16 Model Spd Volts Amps Watts Hp Capacitor 1.8 197 1/6 20μF/180 V 1.5 179 1/6 20μF/180 V 1 1.3 150 1/6 20μF/180 V 3 0.9 196 1/6 5μF/400 V 0.8 179 1/6 5μF/400 V 0.
UPSeries.book Page 58 Monday, March 21, 2011 8:54 PM Technical data UP 26-116 F/BF H [ft] 40 Flow range: 0-37 gpm Head range: 0-37 feet Motors: 2-pole, single-phase 36 Max. liquid temperature: 150 °F (65 °C) 32 Min. liquid temperature: 32 °F (0 °C) 28 Max. system pressure: 145 psi (10 bar) 24 Closed system (F) and Open system (BF) 20 Model 16 UP 26-116 F/BF 12 Amps Watts Hp Capacitor 230 1.8 385 1/6 2.
UPSeries.book Page 59 Monday, March 21, 2011 8:54 PM Technical data UP 26-120 U H [ft] 40 36 Flow range: 0-19 gpm Head range: 0-38 feet Motors: 2-pole, single-phase Max. liquid temperature: 203 °F (95 °C) 32 Min. liquid temperature: 32 °F (0 °C) 28 Max. system pressure: 145 psi (10 bar) 24 Closed system 20 16 Model 12 Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.
UPSeries.book Page 60 Monday, March 21, 2011 8:54 PM Technical data UPS 26-150 F/SF 3 3 2 11 Flow range: 0-53 gpm Head range: 0-46 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Model Spd Volts Amps Watts Hp 3.5 370 1/6 3.1 335 1/6 1 2.5 265 1/6 3 1.7 350 1/6 1.5 310 1/6 1 1.2 250 1/6 3 1.7 370 1/6 1.5 335 1/6 1.
UPSeries.book Page 61 Monday, March 21, 2011 8:54 PM Technical data UP 43-44 F/BF Flow range: 0-68 gpm Head range: 0-13.5 feet 13 Motors: 2-pole, single-phase 12 Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 32 °F (0 °C) 9 Max. system pressure: 145 psi (10 bar) 8 Closed system (F) and open system (BF) H [ft] 14 11 10 7 6 Model 5 Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.
UPSeries.book Page 62 Monday, March 21, 2011 8:54 PM Technical data UPS 43-44 FC/BFC H [ft] 14 Flow range: 0-63 gpm Head range: 0-14 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 32 °F (0 °C) Max. system pressure: 145 psi (10 bar) 3 2 12 10 11 8 Model Spd Volts Amps Watts Hp Capacitor 1.8 203 1/6 20μF/180 V 1.7 189 1/6 20μF/180 V 1 1.4 157 1/6 20μF/180 V 3 0.9 203 1/6 5μF/400 V 0.8 190 1/6 5μF/400 V 0.
UPSeries.book Page 63 Monday, March 21, 2011 8:54 PM Technical data UP 43-70 F H [ft] 25 20 Flow range: 85 gpm Head range: 24.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 14 °F (-10 °C) Max. system pressure: 145 psi (10 bar) Closed system 15 Model 10 Volts Amps Watts Hp Capacitor 115 3.4 400 1/2 30μF 230 1.
UPSeries.book Page 64 Monday, March 21, 2011 8:54 PM Technical data UP 43-75 F/BF Flow range: 0-41 gpm Head range: 0-25 feet 24 Motors: 2-pole, single-phase 22 Max. liquid temperature: 230 °F (110 °C) 20 Min. liquid temperature: 36 °F (2 °C) 18 Max. system pressure: 145 psi (10 bar) H [ft] 26 16 Open system 14 12 Model Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.
UPSeries.book Page 65 Monday, March 21, 2011 8:54 PM Technical data UPS 43-100 F/SF Flow range: 0-65 gpm Head range: 0-31 feet 3 2 Motors: 2-pole, single-phase 1 Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Model Spd Volts Amps Watts Hp Capacitor 3.5 370 1/6 40μF/180 V 3.1 335 1/6 40μF/180 V 1 2.5 265 1/6 40μF/180 V 3 1.7 350 1/6 10μF/400 V 1.5 310 1/6 10μF/400 V 1 1.
UPSeries.book Page 66 Monday, March 21, 2011 8:54 PM Technical data UP 43-110 F H [ft] 40 Flow range: 0-98 gpm Head range: 0-37 feet Motors: 2-pole, single-phase 36 Max. liquid temperature: 230 °F (110 °C) 32 Min. liquid temperature: 14 °F (–10 °C) 28 Max. system pressure: 145 psi (10 bar) 24 Closed system 20 Model Volts Amps Watts Hp Capacitor 115 5.1 590 3/4 60μF 230 2.
UPSeries.book Page 67 Monday, March 21, 2011 8:54 PM Technical data H [ft] UPS 50-44 F 3 3 14 2 2 13 12 11 1 1 10 9 Flow range: 0-65 gpm Head range: 0-14.4 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 32 °F (0 °C) Max. system pressure: 145 psi (10 bar) 8 7 Model Spd Volts Amps Watts Hp 1.7 194 1/6 1.6 181 1/6 1 1.3 147 1/6 3 0.87 195 1/6 0.81 182 1/6 0.
UPSeries.book Page 68 Monday, March 21, 2011 8:54 PM Technical data UPS 50-60 F/SF Flow range: 120 gpm Head range: 21 feet 3 Motors: 2-pole, single-phase 2 Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (10 °C) Max. system pressure: 145 psi (10 bar) Closed or Open system 1 Model Spd Volts Amps Watts Hp 3.6 395 1/6 3.4 350 1/6 1 2.7 260 1/6 3 1.9 395 1/6 1.7 350 1/6 1 1.4 290 1/6 3 1.8 395 1/6 1.7 350 1/6 1.
UPSeries.book Page 69 Monday, March 21, 2011 8:54 PM Technical data UP 50-75 F Flow range: 0-41 gpm Head range: 0-25 feet Motors: 2-pole, single-phase 22 Max. liquid temperature: 230 °F (110 °C) 20 Min. liquid temperature: 32 °F (0 °C) 18 Max. system pressure: 145 psi (10 bar) H [ft] 26 24 16 Closed system 14 12 Model Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.
UPSeries.book Page 70 Monday, March 21, 2011 8:54 PM Accessories UP Series This page intentionally left blank.
UPSeries.book Page 71 Monday, March 21, 2011 8:54 PM Accessories UP Series UP timer Specifications (previous/current) Type: 24 Hr. 3-position On/Timer/Off 15-minute interval • Size: 3.77 x 2.85 x 1.25" • Supply voltage: 120 VAC • Power consumption: 1 VA Switch rating: SPDT • Resistive: 21A/6 A • Tungsten: 1350 W. TM03 4406 3507 • Inductive: 1 HP @ 120 VAC; 2 HP @ 240 VAC Wiring connections: 1/4" quick-connects. Installation Indoor, wired and mounted on the UP terminal box. Fig.
UPSeries.book Page 72 Monday, March 21, 2011 8:54 PM Accessories UP Series AquaStat Specifications 1.082 DIA. Description: Thermostatic switch. ±0.045 0.50 Type: Bi-metallic disc, snap acting. Enclosure: environmentally sealed. Mounting: ±0.250 2.0 • Clip-on mount for 1/2” I.D. copper tube (5/8" O.D.). • Clip-on mount for 3/4” I.D. copper tube (7/8" O.D.). Contact rating: ±0.37 14.0 • 10 A @ 120 VAC, 60 Hz resistive. • 5 A @ 240 VAC, 60 Hz resistive.
UPSeries.book Page 73 Monday, March 21, 2011 8:54 PM Accessories UP Series Pump Zone Controls Approvals Specifications Grundfos Zone Controls are non-networked devices intended to be used for circulator and boiler control in hydronic heating systems.
UPSeries.book Page 74 Monday, March 21, 2011 8:54 PM Accessories UP Series Packaged dielectric isolation valve sets D B C TM04 9909 0311 F E Pump connection Pipe connection type and size NPT Bronze Material Approx. shipping number weight Solder 1/2" GF 15/26 flange TM03 7901 0307 A 96806129 Face to face [A*] Center of port to top [B*] Flange diameter [C*] [lb/oz.
UPSeries.book Page 75 Monday, March 21, 2011 8:54 PM Accessories UP Series Packaged fitting sets GF 15/26/40/43 GF 50 A B Pipe connection 2” NPT D C D Pipe connection E F GU 125 Union TM04 9810 0111 TM04 9808 0111 A B Isolation Valve GU 125 Union Pipe connection Pipe connection D D A C B Material Pump Connection Pipe Connection NPT Solder Compression 3/4" GF15/26 Cast Iron Material Number TM04 9811 0111 TM04 9809 0111 A B C Dimensions (in.
UPSeries.book Page 76 Monday, March 21, 2011 8:54 PM Accessories UP Series UP-ZV zone valves Specifications Grundfos UP-ZV 24V, 2-way motorized zone valves for hydronic heating or chilled water applications. Standard features • In-line removable actuator for ease of installation and service • manual open/close lever • sealed end switch • silent close-of technology • high gear ratio • forged brass body • removable service cap • high Cv rating. TM04 9803 0111 Approvals Technical data Max.
UPSeries.book Page 77 Monday, March 21, 2011 8:54 PM Accessories UP Series UP-ZV flow characteristics Max. Close-off ΔP Connection size Flow Coefficient 1/2-inch Sweat 3.5 Cv (3.0 Kv) 30 psi (207 kPa) 3/4-inch Sweat 7.5 Cv (6.5 Kv) 20 psi (138 kPa) 1-inch Sweat 7.5 Cv (6.5 Kv) 20 psi (138 kPa) 3/4-inch NPT 3.5 Cv (3.
UPSeries.book Page 78 Monday, March 21, 2011 8:54 PM Accessories UP Series Replacement flange gaskets 78 For use with flange set Material number Description Shipping weight [oz.
UPSeries.book Page 79 Monday, March 21, 2011 8:54 PM Submittal data UP Series Submittal data Company name ................................................. Prepared by ....................................................... Phone number (.......)......................................... Fax number (.......).............................................. Date:..................... Page 1 of:.................... Quote number:...................................................
UPSeries.book Page 80 Monday, March 21, 2011 8:54 PM Submittal data UP Series This page intentionally left blank.
UPSeries.book Page 81 Monday, March 21, 2011 8:54 PM Further product documentation UP Series WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: • Catalog • Literature • Service • Sizing • Replacement • CAD drawings.
UPSeries.book Page 82 Monday, March 21, 2011 8:54 PM Further product documentation Sizing 0 UP Series 1 This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to • select the most suitable and efficient pump for your installation • carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc.
UPSeries.
UPSeries.book Page 116 Monday, March 21, 2011 8:54 PM Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence L-UP-PG-001 Rev. 0311 US Repl. 1109 © 2007, 2009-2010 Grundfos Pumps GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: +1-913-227-3400 Telefax: +1-913-227-3500 www.grundfos.com GRUNDFOS Canada Inc.