5 SQF-8 data sheet

Performance curve for the 5 SQF-8
Specications
Pump type Motor
type
Maximum
power input
P1 (W)
Maximum
current
(A)
5 SQF-8 MSF 3 (N) 300 8.4
Power supply to pump 30 - 300 V DC, PE
1 x 90 - 240 V, -10 %/+6 %, 50/60 Hz, PE
Power consumption Max. 300 W
Current consumption Max. 8.4 A
Run-up time Depends on the energy source
Start/stop No limitation to the number of starts/stops per hour
Enclosure class IP68
Conductivity ≥70 µs/cm (micro Siemens)
Sound pressure level The sound pressure level of the pump is lower than the limiting values stated in the
EC Machinery Directive
Radio noise The SQF complies with the EMC Directives 2014/30/EU
Tested according to the standards EN 61000-3-2:2014 and EN 61000-3-3:2013
EN55014-1:2006 + A1:2009 + A2:2011
EN55014-2:1997 + A1:2001 + A2: 2008
Reset function The SQF can be reset via the CU200 or by disconnecting the power supply for 1 minute
Power factor PF = 1
Operation via generator Voltage: 230 V AC -10 % / +6 %
The generator output must be minimum 1.55 kV A
Earth-leakage circuit breaker If the pump is connected to an electric installation where an earth-leakage circuit (ELCB)
is used as an additional protection, this circuit breaker must trip out when earth fault
currents with DC content (pulsating DC) occur
Borehole diameter Minimum 76 mm/3 inches
Installation depth The pump must at a minimum be completely submerged in the pumped liquid
Suction strainer Holes of the suction strainer: Ø 2.5
Pumped liquids pH 5 to 9, media temperature max. 104 °F
Sand content up to 50 ppm
Marking CE
0.08 0.10 0.12 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.32 0.34 0.36 0.38 0.40
P1 [hp]
0
1
2
3
4
5
6
7
8
9
10
[US GPM]
Q
0.0
0.5
1.0
1.5
2.0
[m³/h]
Q
60 80 100 120 140 160 180 200 220 240 260 280
P1 [W]
5 SQF-8
35 ft
50 ft
65 ft
100 ft
130 ft
15 ft
TM06 8848 1217