TP80-40/4 Shaft Seals Manual

34
Types of shaft seals
Shaft seals
Type H for ø12, ø16 and ø22 mm shaft with SiC/
carbon seal faces
Suitable for use in CR/CRI/CRN pumps, the seal is rec-
ommended for use in very hot water (above 100°C).
Can be replaced without dismantling the pump part.
There is no relation between the indication of suitability
and the pressure-temperature diagram, but together
they form the application profile.
Suitability
Pressure-temperature diagram
The pressure-temperature diagram is based on clean
water. At temperatures below freezing point, the dia-
gram is based on a mixture of water and glycol.
The figures in the following table refer to the pressure-
temperature diagram.
Fig. 47
Pressure-temperature diagrams
Type H for ø12, ø16 and ø22 mm shaft with tungsten
carbide/carbon seal faces
Suitable for use in CR/CRI/CRN pumps, the seal is rec-
ommended for use in very hot water (above 100°C).
Can be replaced without dismantling the pump part.
There is no relation between the indication of suitability
and the pressure-temperature diagram, but together
they form the application profile.
Suitability
Pressure-temperature diagram
The pressure-temperature diagram is based on clean
water. At temperatures below freezing point, the dia-
gram is based on a mixture of water and glycol.
The figures in the following table refer to the pressure-
temperature diagram.
Fig. 48
Pressure-temperature diagrams
Suitable
Suitable under
certain
conditions
Not
suitable
Alkaline liquids
Acid liquids
Dry running
Solid particles in liquid
Precipitating/lime-
containing liquids
Anti-freeze liquids
Pos.
Recommended service intervals
[operating hours] before wear-out
1 14,000 - 20,000
2 8,000 - 14,000
3 4,000 - 8,000
TM02 8445 0204
[bar]
30
25
20
15
10
5
0
0 10 20 30
2
40 50 60 70 80 90 100 110 120 130 140 150
3
1
[˚C]
30
25
20
15
10
5
0
[˚C]
1
2 3
0
10 20 30 40 50 60 70 80 90 100 110120 130 140 150
1
[bar]
12/16 mm
22 mm
Suitable
Suitable under
certain
conditions
Not
suitable
Alkaline liquids
Acid liquids
Dry running
Solid particles in liquid
Precipitating/lime-
containing liquids
Anti-freeze liquids
Pos.
Recommended service intervals
[operating hours] before wear-out
1 14,000 - 20,000
2 8,000 - 14,000
3 4,000 - 8,000
TM02 8446 0204
[bar]
30
25
20
15
10
5
0
0 10 20 30
2
40 50 60 70 80 90 100 110 120 130 140 150
3
1
[˚C]
12 mm
16 mm
30
25
20
15
10
5
0
[˚C]
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
[bar]
1
1
2
3
22 mm
30
25
20
15
10
5
0
[˚C]
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
[bar]
2
1
1
3
2