Installation and Operating Instructions
Table Of Contents
- English (GB)
- 1. General information
- 2. Installing the product
- 3. Starting up the product
- 4. Product introduction
- 5. Control functions
- 5.1 Application types
- 5.2 Setting the sensor type
- 5.3 Setting the start level
- 5.4 Setting the stop level
- 5.5 Setting the high level
- 5.6 Stop delay
- 5.7 Power-on delay
- 5.8 Dry-running protection
- 5.9 Using the same level switch for the start and stop level
- 5.10 "Multipump settings"
- 5.11 "Antiseizing"
- 5.12 Signal detection time
- 5.13 Setting the maximum number of restarts with Grundfos GO Remote
- 5.14 Motor protection
- 5.15 Alarm reset
- 5.16 Setting the buzzer with Grundfos GO Remote
- 5.17 Setting units for Grundfos GO Remote
- 5.18 Setting units for the operating panel with Grundfos GO Remote
- 5.19 GENIbus
- 5.20 Security
- 5.21 Starting the startup wizard with the operating panel
- 6. Operating the product
- 7. Servicing the product
- 8. Fault finding the product
- 8.1 Overview of alarm and warning codes
- 8.2 Code 2 (Power phase missing)
- 8.3 Code 4 (Too many motor restarts)
- 8.4 Code 9 (Power phase sequence wrong)
- 8.5 Code 12 (Service needed)
- 8.6 Code 22 (Moisture in motor of pump)
- 8.7 Code 25 (Wrong configuration)
- 8.8 Code 48 (Motor is overloaded)
- 8.9 Code 57 (Missing water in the application)
- 8.10 Code 69 (Winding temperature too high)
- 8.11 Code 84 (Memory storage media faulty)
- 8.12 Code 117 (Door opened)
- 8.13 Code 159 (Communication error CIMxxx)
- 8.14 Code 165 (Signal fault)
- 8.15 Code 191 (High water level)
- 8.16 Code 205 (Level switch inconsistency)
- 8.17 Code 225 (Communication error pump module)
- 8.18 Code 226 (Communication error IO module)
- 8.19 Code 229 (Water on floor)
- 9. Technical data
- 10. Disposing of the product
English (GB) Installation and operating instructions
Original installation and operating instructions
Table of contents
1. General information ........................4
1.1 Hazard statements..........................4
1.2 Notes ..................................5
2. Installing the product .......................5
2.1 Location ................................5
2.2 Mechanical installation .......................5
2.2.1 Mounting the control unit ......................5
2.2.2 Installing a communication interface module ..........5
2.3 Electrical connections ........................6
2.3.1 Connecting the power supply ...................6
3. Starting up the product ......................6
3.1 Setting the product..........................6
3.1.1 Connecting to Grundfos GO Remote...............6
3.1.2 Startup wizard on Grundfos GO Remote ............7
3.1.3 Startup wizard on the operating panel ..............7
3.1.4 How to enable Bluetooth on the operating panel........7
3.1.5 How to disable Bluetooth on the operating panel .......7
3.1.6 Setting the service interval with Grundfos GO Remote . ...7
3.2 Testing the product..........................7
4. Product introduction........................7
4.1 Operating panel ...........................7
4.2 Terminals ...............................8
4.3 Product description .........................8
4.4 Intended use .............................8
4.5 Features ................................8
4.6 Identification..............................8
4.6.1 Nameplate...............................8
4.6.2 Type key ................................8
4.7 Supported communication interface modules and
protocols ................................9
5. Control functions ..........................9
5.1 Application types ...........................9
5.1.1 Setting the application type with Grundfos GO Remote. ...9
5.2 Setting the sensor type .......................9
5.2.1 Setting the sensor type with Grundfos GO Remote ......9
5.2.2 Setting the sensor type using the operating panel .......9
5.3 Setting the start level .......................10
5.3.1 Setting the start level with Grundfos GO Remote ......10
5.3.2 Setting the start level with the operating panel ........10
5.4 Setting the stop level .......................10
5.4.1 Setting the stop level with Grundfos GO Remote ......10
5.4.2 Setting the stop level with the operating panel ........10
5.5 Setting the high level .......................10
5.5.1 Setting the high level with Grundfos GO Remote ......10
5.5.2 Setting the high level with the operating panel ........10
5.6 Stop delay ..............................10
5.6.1 Setting the stop delay with Grundfos GO Remote ......10
5.7 Power-on delay ...........................10
5.7.1 Setting the power-on delay with Grundfos GO Remote. ..10
5.8 Dry-running protection.......................10
5.8.1 Setting the dry-running level with Grundfos GO Remote ..11
5.8.2 Setting the dry-running level with the operating panel....11
5.9 Using the same level switch for the start and stop level ..11
5.10 "Multipump settings" ........................11
5.10.1Setting "multipump settings" with Grundfos GO Remote ..11
5.11 "Antiseizing".............................11
5.11.1 Setting the "Anti-seizing" function with Grundfos GO
Remote................................11
5.12 Signal detection time .......................11
5.12.1Setting the signal detection time with Grundfos GO
Remote................................11
5.13 Setting the maximum number of restarts with Grundfos
GO Remote .............................11
5.14 Motor protection ..........................11
5.14.1Overheat protection ........................11
5.14.2Overload protection ........................11
5.14.3Moisture protection.........................11
5.14.4Setting the motor protection with Grundfos GO Remote ..11
5.15 Alarm reset .............................12
5.15.1Resetting alarms and warnings manually with Grundfos
GO Remote .............................12
5.15.2Setting the automatic alarm reset with Grundfos GO
Remote................................12
5.15.3Resetting alarms and warnings on the operating panel . ..12
5.16 Setting the buzzer with Grundfos GO Remote ........12
5.17 Setting units for Grundfos GO Remote.............12
5.18 Setting units for the operating panel with Grundfos GO
Remote................................12
5.19 GENIbus ...............................12
5.19.1Setting the GENIbus address with Grundfos GO
Remote................................12
5.20 Security ...............................12
5.20.1Locking the operating panel ...................12
5.20.2Unlocking the operating panel ..................12
5.20.3Locking Grundfos GO Remote..................12
5.20.4Unlocking Grundfos GO Remote ................13
5.21 Starting the startup wizard with the operating panel .....13
6. Operating the product ......................13
6.1 Manual operation..........................13
6.1.1 Starting and stopping the pump manually with Grundfos
GO Remote .............................13
6.1.2 Automatic operation ........................13
6.1.3 Starting and stopping the pump manually with the
operating panel ...........................13
6.1.4 Choosing what the pump must do after manual start ....13
7. Servicing the product ......................13
7.1 Updating the product software..................13
7.2 Replacing the control unit.....................13
7.3 Replacing the CIM module ....................13
7.4 Replacing the battery .......................14
8. Fault finding the product ....................14
8.1 Overview of alarm and warning codes .............14
8.2 Code 2 (Power phase missing) .................14
8.3 Code 4 (Too many motor restarts) ...............14
8.4 Code 9 (Power phase sequence wrong)............14
8.5 Code 12 (Service needed) ....................14
8.6 Code 22 (Moisture in motor of pump) .............15
8.7 Code 25 (Wrong configuration) .................15
8.8 Code 48 (Motor is overloaded) .................15
8.9 Code 57 (Missing water in the application) ..........15
8.10 Code 69 (Winding temperature too high) ...........15
8.11 Code 84 (Memory storage media faulty)............15
8.12 Code 117 (Door opened) .....................15
8.13 Code 159 (Communication error CIMxxx) ...........15
8.14 Code 165 (Signal fault) ......................15
8.15 Code 191 (High water level) ...................16
8.16 Code 205 (Level switch inconsistency) ............16
8.17 Code 225 (Communication error pump module) .......16
8.18 Code 226 (Communication error IO module) .........16
8.19 Code 229 (Water on floor) ....................16
9. Technical data ...........................16
10. Disposing of the product ....................16
1. General information
STATUS-NOT-SET | Hazard-statements-(co)-zGZvhS8.dita
1.1 Hazard statements
The symbols and hazard statements below may appear in Grundfos
installation and operating instructions, safety instructions and
service instructions.
4
English (GB)