STATUS-NOT-SET | Code-191-(High-water-level)-(ts)-AONKraA.dita
8.15 Code 191 (High water level)
Alarm code 191 is shown on the display.
The alarm symbol on the display turns red, but the pump's
operating mode is unchanged.
Alarm code High water level is displayed in Grundfos GO
Remote.
Cause The defined start level did not start the pump.
Remedy Check and configure the sensor for start level.
Cause The pump is not big enough to remove the
water.
Remedy Contact Grundfos or an authorised service
workshop.
STATUS-NOT-SET | Code-205-(Level-switch-inconsistency)-(ts)-ADPyIUk.dita
8.16 Code 205 (Level switch inconsistency)
Alarm code 205 is shown on the display.
The alarm symbol on the display turns red and the pump
stops.
Alarm code Level switch inconsistency is displayed in
Grundfos GO Remote.
Cause A float switch could be defective or stuck.
Remedy Check the functionality of each float switch.
STATUS-NOT-SET | Code-225-(Communication-error-IO-module)-(ts)-f65Db08.dita
8.17 Code 225 (Communication error pump module)
Alarm code 225 is shown on the display.
The alarm symbol on the display turns red and the pump
stops.
Alarm code Communication error is displayed in Grundfos
GO Remote.
The pump module is unable to communicate with the product.
Cause
The pump module is installed incorrectly.
Remedy Ensure that the module, including cables, is
fitted correctly.
Cause The pump module is defective.
Remedy Contact Grundfos.
STATUS-NOT-SET | Code-226-(Communication-error-IO-module)-(ts)-5C5bI3w.dita
8.18 Code 226 (Communication error IO module)
Alarm code 226 is shown on the display.
The alarm symbol on the display turns red and the pump
stops.
Alarm code Communication error is displayed in Grundfos
GO Remote.
The pump module is unable to communicate with the product.
Cause
The IO module is installed incorrectly.
Remedy Ensure that the module, including cables is
fitted correctly.
Cause The IO module is defective.
Remedy Contact Grundfos.
STATUS-NOT-SET | Code-229-(Water-on-floor)-(ts)-AP90vmI.dita
8.19 Code 229 (Water on floor)
Warning code 229 is shown on the display if you press
the Up or Down button.
The warning symbol on the display turns yellow and the pump's
operating mode is unchanged.
Warning code Water on floor is displayed in Grundfos GO
Remote.
Cause
The sensor detects water on the floor.
Remedy Check for water leakage.
STATUS-NOT-SET | Technical-data-for-CU-241-(re)-Itw2Pw4.dita
9. Technical data
Supply voltage
24 VDC, - 10 %/+ 10 %.
Power supply is required to be class 2.
Check that the supply voltage corresponds to the values stated on
the nameplate.
Maximum power dissipation
Object Maximum power dissipation
99347488 9.4 W
Enclosure class
IP54, 3R for CU 241 built into panel of similar or higher enclosure
class.
GENIbus terminal
- 7 VDC to + 12 VDC.
Nominal current condition: 4 mADC.
Short-circuit current condition: 328mA.
Dimensions
187
137
52
TM072339
Related information
7.4 Replacing the battery
STATUS-NOT-SET | Disposing-the-product-(ta)-OjaaorI.dita
10. Disposing of the product
This product or parts of it must be disposed of in an environmentally
sound way.
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest Grundfos company or
service workshop.
3. Dispose of the waste battery through the national collective
schemes. If in doubt, contact your local Grundfos company.
See also end-of-life information at www.grundfos.com/product-
recycling.