Owner's Manual

1
3
2
4
Unscrew sediment and carbon
lter housings using supplied
lter wrench. Wash inside of lter
housings to remove debris.
Tighten lter housings by hand,
do not use lter wrench. Do not
over tighten.
Install new sediment and carbon
lter, making sure they go into
the correct lter housings.
Clean o’ring and o’ring seat, then
re-grease with food grade silicon
grease.
Sediment
Carbon
O-ring
6
Pre-lters should be changed when either brown discoloration occurs,
or system ow rates have signicantly declined.
Always turn incoming water pressure o before servicing the unit.
Always turn incoming water pressure on slowly, allowing all air to be
discharged before full water pressure is restored.