Owner's Manual

MODEL SPECIFICATIONS
• RO Water System
• De-ionization
• Rinse Water
• Hot/Cold Water Dispenser
• Coee Machine
• Wash Water
• Water purication System
• Potable Water
• Bottle Water
NOTICES:
When the GX UV is installed and running, the rst 280cc of water will be warmer than normal.
When the system to which the UV is connected is not in use, the water will warm up after 25
minutes. You may ush the GX System lter before use to remove the warmer water.
Do not look directly at the ultraviolet rays emitting from the UV lamp or it may cause eye damage.
Unplug the UV electrical cord before servicing and/or cleaning the UV lamp or housing.
ELECTROMAGNETIC WAVE DRAWING
PART # IN / OUT VOLTAGE BALLAST
FLOW
RATE
MAXIMUM
OPERATING
PRESSURE
LAMP LIFE
AUDIBLE LAMP
ALARM
UV-1530 1/4” NPT
110V~120V / 60HZ
220V~240V (special
order)
6W 1 GPM 85psi 5,000 hrs. No
UV-6010 1/4” NPT
110V~120V / 60HZ
220V~240V (special
order)
14W 2 GPM 125psi 9,000 hrs. yes
UV-LB 1/2” NPT
110V~120V / 60HZ
220V~240V (special
order)
24W 4 GPM 125psi 9,000 hrs. yes
UV-XL 1/2” NPT
110V~120V / 60HZ
220V~240V (special
order)
32W 6 GPM 125psi 9,000 hrs. yes
UV-12 3/4” MNPT
110V~120V / 60HZ
220V~240V (special
order)
39W 12 GPM 125psi 9,000 hrs. yes
6