Instruction Manual
1. WHAT CAUSES THE DDP-20 TO START?
The DDP-20 has the built-in pressure switch and internal ow switch.
Each of these can turn the pump on depending on water consumption.
The pump will start when:
- The pressure is BELOW the pressure switch activation point. OR
- The ow rate is greater than 0.7 GPM.
2. WHAT CAUSES THE DDP-20 TO STOP?
The ow switch is designed to automatically stop the DDP-20 when ow drops to below 0.7 GPM.
The DDP-20 is programmed to stop after 8 seconds. In addition, the DDP-20 will be turned o in the event of
dry-run or over temperature alarm.
3. WHAT IS THE PURPOSE OF THE BUILT-IN PRESSURE TANK?
The pressure tank comes from the factory pressurized at approximately 20 psi (with the pump pressure at
zero). It is designed to minimize motor startup due to small ow demand or minor leak of the pipeline.
4. HOW IS THE DRY-RUN CONDITION DETERMINED AND THE PROTECTION
PROVIDED?
The dry-run is dened when the motor is running AND the ow rate is less than 0.3 GPM AND when pressure
is less than the pressure switch setting.
The protection is provided:
• When the pump is run dry 2 minutes, it will automatically shut o for 10 minutes and then attempts to
restart.
• When all 3 attempts are failed, the pump will rest for 1 hour and then attempts to restart.
• This protection mode will be repeated until the water supply is back to normal.
In case the pump is cycling (on-and-o repeatedly) due to small ow (less than 0.3GPM), air pocket in the
system, air loss in the pressure tank or leak in the pipeline, the protection is provided:
• The pump will run for 8 seconds and stop for about 3 seconds.
• When the cycling mode repeats for 15 times consecutively, the pump will rest for 1 hour.
• Then it will start over the protection mode until the problem is corrected.
Note: The pump can be reset anytime by removing the power plug.
5. WHAT IS THE MAXIMUM INLET PRESSURE ALLOWED IN THE DDP-20?
• The maximum internal system pressure allowed for DDP-20 is 120 psi.
• The maximum inlet pressure when added to the DDP-20 pressure must not exceed 120 psi.
For example with a 40 psi inlet pressure supplied to the pump, internal system pressures can reach
approximately 107 psi (67 + 40 psi). Additionally, if inlet pressures exceed the built-in pressure switch
activation point (20 psi factory default), the pressure switch will be unable to function, and the ability to turn
the DDP-20 on at low ow rates will be lost. In this situation, only the ow switch will be able to turn the DDP-
20 on at ow rates above 0.7 gpm.