WARNING
Risk of electric shock - This pump has not been investigated for use in swimming pool or marine areas.
To reduce the risk of lectric shock, connect only to a properly grounded, grounding-type receptacle.
Before operation, please ensure the voltage is correct and the circuit breaker and grounding
connectors are all connected in accordance with local regulations.
1. Ensure the mains voltage is the same as the value shown on the motor plate and that the pump is safely
connected to ground/earth.
2. The single phase models are supplied with plug and lead and can be connected directly to the mains
supply. The 3 phase models should hook up with a circuit breaker.
ELECTRICAL
This mark located outside the connection box is a warning for an electrical hazard.
Part #
Plumbing
In / Out
Voltage Amps
Flow
Rate
High
Pressure
Cuto
Duty
Cycle
DDP-20 1” NPT 120 VAC 10A 20 GPM Yes Constant
VI. STARTING
a. Remove the lling plug b. Fill water in chamber c. Replace the lling plug
Torque:
26 in-lb
Fig. 6Fig. 6Fig. 8Fig. 8
Before starting, the pump must be primed. For installation with no inlet pressure, please follow the procedure
as shown in Fig. 8.
1. For installation with inlet pressure, remove the priming plug and allow the water to ow into the priming
chamber until all air is expelled.
2. The priming procedure should be repeated until all air is expelled and the pump delivers a full stream of
water without bubbles.
3. The pump must always be checked for prime if not used for a prolonged period. It is imperative to ll the
pump with liquid before operation as dry running causes irreparable damage to the mechanical seal.