Owner's Manual

4
The BP-6010 series of Booster Pumps are designed for use with all GrowoniX EX1000 & GX1000
water lters.
The pump is designed to boost low water pressure conditions to optimal pressure.
Do not exceed 150 psi output pressure.
ABOUT
CAUTIONS
MOUNTING
The pump is equipped with an adjustable bypass valve which controls the maximum operating
pressure. In addition, never subject the pump to pressures above 150 PSI.
Never operate the pump in a harsh environment or hazardous atmosphere,
since motor brush and switch may cause electrical arcing.
Pumphead materials are designed for use with water only. Do not use with petroleum products.
Always consider electrical shock hazard when working with and handling electrical equipment.
If uncertain, consult an Electrician. Electrical wiring should only be done by a qualied Electrician
per Local and State Electrical Codes.
The pump should be mounted in a dry place and away from any source of heat. If an enclosure is
used, special provisions for cooling the motor may be necessary. Consult the Factory.
Do not subject the pump to extreme high or low (freezing) temperatures while in operation.
(Operating ambient temperature range is 32ºF to 115ºF).
The pump may be mounted in the vertical or horizontal position.
READ ENTIRE MANUAL THOROUGHLY
BEFORE INSTALLING THIS HIGH PRESSURE-BOOSTING PUMP.
INSERT TUBE INTO FITTING
Push the tubing through the collet and dual o-rings until it bottoms
out against the tube stop.
The collet holds the tube in place and the dual o-rings provide a leak
resistant seal.
MAKE A CLEAN TUBE CUT
Cut the tube squarely and if using plastic tubing, ensure that the cut has
not made the tube out of round.
Also ensure that the tube has a smooth outside diameter without any
burrs or score marks prior to inserting it into the tting.
TEST AND INSPECT
Push and pull the tubing toward and away from the tting to ensure
that it has been installed properly.
Test and inspect the installation for any leaks.
TUBE REMOVAL
Relieve pressure from the tubing and tting. Push uniformly around
the collet ange against the tting body while pulling the tubing away
from the tting to release it.
O-RING
COLLET
TUBING
PUSH COLLET IN
PULL TUBE OUT
GROWONIX WATER FILTERS USE QUICK CONNECT FITTINGS
THAT ALLOW FOR EASY MAINTENANCE.
4
Built in the U.S.A.
BASIC INFORMATION