Owner's Manual

Normaly closed oat switches are closed while hanging
“down”, and will open on a rising liquid level—typically used for
“tank lling” applications.
1. Determine the desired cord tether length . See Figure 2.
2. Attach the Pipe Clamp at the desired location. See Figure 1.
3. Adjust the tether length to achieve the desired pumping
range. Use Figure 2 as a guide and test the system by lling
tank and cycling the system to achieve the actual desired
pumping range. Tighten the clamp
FIGURE 2
Tether
Length
Pumping
Range
4" 8"
5" 9"
6" 10"
7" 11"
8" 12"
9" 13"
10" 14"
11" 15"
12" 16"
13 17"
14" 18"
15" 19"
16" 20"
17" 21"
18" 22"
FIGURE 1
1. Remove the garden hose tting from the water lter input and attach the supplied SCH80 PVC as
shown above.
2. Install the solenoid valve on the input of the EX/GX1000, making sure valve is installed in the
correct direction of ow. (see arrow stamped on valve housing and reference pg. 13).
3. Make sure the override switch is in the “Normal Operation” position (see: page 13).
4. Turn on feed water supply and check for leaks in the solenoid valve water connections.
(ESOK) ELECTRIC SHUT OFF KIT CONNECTION
*
*
DISCONECT PUMP AND ALL COMPONENTS FROM ELECTRICAL SUPPLY,
AND TURN OFF FEED WATER SUPPLY BEFORE CONNECTING THE ESOK.
WARNING:
Read instructions thoroughly. Check local codes and install to meet requirements.
Turn o all power when installing or adjusting unit.
Failure to turn o all power could result in serious injury or death!
End user to provide overcurrent protection rated at 120VAC
minimum, 15 Amps maximum.
INSTALLING THE FLOAT BALL SWITCH
14
Built in the U.S.A.
INSTALLING THE SOLENOID VALVE