Owner's Manual

The bypass valve, located on the input side of the pump can be used to regulate pump output
pressure. It is adjustable with a at head screwdriver.
WHILE REFERENCING THE PUMP PRESSURE GAUGE:
1. Turn the screw clockwise to INCREASE system pressure.
2. Turn the screw counterclockwise to DECREASE system pressure.
PUMP OUTPUT PRESSURE ADJUSTMENT
BP-6010 PUMP
BP-6010-CH PUMP
MINIMUM SYSTEM PRESSURE IS 40PSI.
MAXIMUM SYSTEM PRESSURE IS 150 PSI.
Running the system at higher pressure will result in failure of ttings, overheating of the pump
motor, and possible injury.
As membranes foul, system pressure increases. Make sure you leave some headroom so that a
pressure increase due to fouling DOES NOT EXCEED 150 PSI.
12
Built in the U.S.A.