BP-6010 Bp-6010-CH ESOK Owners Manual w w w. g r o w on i x . c o m Built in the U.S.A. www.growonix.com toll free 888.406.8521, office 818.510.0264, sales@growonix.
INTRODUCTION OUR MISSION Durability, Reliability, Efficiency, Purity, and Conservation form the foundation on which we design and build all of our products. Consistent and superior quality sets us apart from other manufacturers and increases our value to you - our customer. Whether you are a hydroponics hobbyist, serious enthusiast, or large-scale gardener, GrowoniX is committed to bringing you the best solution for water purification systems.
FEATURES FEATURES: DOUBLES PURE WATER PRODUCTION FOR ALL 600-1000 GPD SYSTEMS-MAX 2000 GPD. ONLY NEEDS 30PSI OF INCOMING WATER PRESSURE TO PRODUCE THE FULL FLOW RATE. LOW-PRESSURE CUTOFF TO SAFEGUARD AGAINST A LOSS OF INCOMING WATER PRESSURE. STAINLESS STEEL LIQUID-FILLED 300PSI PRESSURE GUAGE.
BASIC INFORMATION READ ENTIRE MANUAL THOROUGHLY BEFORE INSTALLING THIS HIGH PRESSURE-BOOSTING PUMP. ABOUT • • • The BP-6010 series of Booster Pumps are designed for use with all GrowoniX EX1000 & GX1000 water filters. The pump is designed to boost low water pressure conditions to optimal pressure. Do not exceed 150 psi output pressure. CAUTIONS • • • • The pump is equipped with an adjustable bypass valve which controls the maximum operating pressure.
PLUMBING AND ELECTRICAL PLUMBING • • The input to the BP-6010 pump is 1/2 OD” tubing size. The output is 3/8” OD tubing. the ESOK is 3/4” or 1”. CAUTIONS • • Do not use garden hose fittings or attachements when using a BP-6010 series pump, especially when using an ESOK (electric shutoff kit). It is only recomended to plumb he RO system with appropriate SCH40/80 PVC, copper, or CTS pipe suitable to pass local plumbing inspections in your area.
BP-6010 INFORMATION * THE PUMP MUST NEVER BE RUN DRY. OPERATING THE PUMP WITHOUT SUFFICIENT FEED WATER WILL DAMAGE THE PUMP. ALWAYS FEED THE PUMP FILTERED WATER. THE PUMP IS SUSCEPTIBLE TO DAMAGE FROM SEDIMENT AND DEBRIS. * IF ANY DAMAGE OCCURS TO YOUR SYSYTEM’S PUMP, A RE-BUILD KIT MAY BE AVAILABLE. CONTACT YOUR LOCAL DEALER OR DISTRIBUTOR AND INFORM THEM OF YOUR SYSTEM’S MODEL AND PUMP SIZE. • • • The pump is a low-lead brass rotary vane pump. This pump is also available in stainless steel.
COMPONENT DIAGRAM 4 3 2 1 6 5 1 3 2 4 7 8 5 6 9 7 8 9 1. 2. 3. 4. 5. 6. 7. 8. 9. Motor 1/2” Pump Input (connection to pre filter housing output) 3/8” Pump Output (connection to membrane input) Output Pressure Gauge Low Pressure Switch Pump Pressure Bypass Adjustment Pump Power On/Off Switch AC Cord Piggyback Cord for ESOK (Solenoid Valve Shutoff Kit) READ ENTIRE MANUAL THOROUGHLY BEFORE INSTALLING THIS HIGH PRESSURE-BOOSTING PUMP. Built in the U.S.A.
SETUP INSTRUCTIONS FOR BP-6010 IMPORTANT TIPS: TURN OFF INCOMING WATER SUPPLY AND DRAIN SYSTEM PRESSURE BEFORE INSTALLING A BP-6010 PUMP 1 2 Slide the 1/2” locking clip off of the carbon filter output fitting, and remove the short length of 1/2” tubing feeding the membrane input. 3 4 Cut the tubing to the appropriate length (ensure no kinks or flow restrictions), and insert into the 1/2” pump input. Install the 1/2” locking clip. 8 Insert the supplied 1/2” tubing into the carbon filter output.
6 5 Cut the 3/8” tubing to the appropriate length (ensure no kinks or flow restrictions), and install the 1/2” x 3/8” stem reducer onto the 3/8” tubing. Insert the stem reducer into the 1/2” membrane input fitting. Complete assembly as shown, with red locking clips in the correct places. Built in the U.S.A.
SETUP INSTRUCTIONS FOR BP-6010-CH TURN OFF INCOMING WATER SUPPLY AND DRAIN SYSTEM PRESSURE BEFORE INSTALLING A BP-6010 PUMP 1 2 Attach BP-6010-CH chassis to GX600/1000 housing using the existing caster hardware. Install the caster onto the chassis bottom. 3 4 Slide the 1/2” locking clip off of the carbon filter output fitting, and remove the short length of 1/2” tubing feeding the membrane input.
Attach BP-6010-CH chassis to GX600/1000 housing. Replace caster nut and washer and tighten. 7 8 Cut the 3/8” tubing to the appropriate length (ensure no kinks or flow restrictions), and install the 1/2” x 3/8” stem reducer onto the 3/8” tubing. Insert the stem reducer into the 1/2” membrane input fitting. Built in the U.S.A. Complete assembly as shown, with red locking clips in the correct places.
PUMP OUTPUT PRESSURE ADJUSTMENT BP-6010 PUMP BP-6010-CH PUMP The bypass valve, located on the input side of the pump can be used to regulate pump output pressure. It is adjustable with a flat head screwdriver. WHILE REFERENCING THE PUMP PRESSURE GAUGE: 1. Turn the screw clockwise to INCREASE system pressure. 2. Turn the screw counterclockwise to DECREASE system pressure. MINIMUM SYSTEM PRESSURE IS 40PSI. MAXIMUM SYSTEM PRESSURE IS 150 PSI.
ELECTRIC SHUT OFF KIT COMPONENT DIAGRAM 3 1 direction of flow 5 2 1. 2. 3. 4. 5. SOLENOID VALVE FLOAT BALL SWITCH FLOAT BALL PIGGYBACK CORD SOLENOID VALVE MANUAL OVERRIDE SWITCH SOLENOID VALVE (DIRECTION OF FLOW) SOLENOID MANUAL OVERRIDE SWITCH NORMAL OPERATION MANUAL OVERRIDE 4 Built in the U.S.A.
(ESOK) ELECTRIC SHUT OFF KIT CONNECTION * * DISCONECT PUMP AND ALL COMPONENTS FROM ELECTRICAL SUPPLY, AND TURN OFF FEED WATER SUPPLY BEFORE CONNECTING THE ESOK. INSTALLING THE SOLENOID VALVE 1. Remove the garden hose fitting from the water filter input and attach the supplied SCH80 PVC as shown above. 2. Install the solenoid valve on the input of the EX/GX1000, making sure valve is installed in the correct direction of flow. (see arrow stamped on valve housing and reference pg. 13). 3.
(ESOK) WIRING DIAGRAM 2 3 2 ESOK ELECTRICAL CONNECTION 3 1. Attach the float ball piggyback cord to the male plug end from the pump control box.(2) The float switch will now govern whether current will flow to the pump control box or not. 2. Plug the solenoid valve into the female plug end extending from the pump control box (3). • Float ball facing “UP” = current does not flow (pump off). • Float ball facing “DOWN” = current flows (pump on).
GROWONIX SYSTEM WARRANTY For a period of one year from the date of original purchase, we will replace or repair any part of the GrowoniX product that we find to be defective in operation due to faulty materials or workmanship with the exception of the replaceable filters and membranes.