Owner manual

Shaft Connections
providesuitableguardsinaccordancewithOSHAstandards.
Inputandoutputshaftextensiondiametertoleranceis+0.000”;-0.001”forshaftsupto1.375”diameter.Thefittedcomponentmustbemachinedtoensure
proper fit.
DONOTdrivecouplinghub,pinion,sprocketorpulleyontheshaft.Anendwiseblowon the shaftmaydamagegearsandbearings.Couplinghubs,
pinions,sprocketsorpulleysmustbepushedontotheshaftusingascrewjackdevicefittedintothethreadedholeprovidedintheendoftheshaft,see
Table3below.
Output Shaft Input Shaft
Drive Size Tap Size Depth Tap Size Depth
717 1/4-20 .62 1/4-20 .62
727 5/16-18 .75 1/4-20 .62
747 5/16-18 .75 5/16-18 .75
757 5/16-18 .75 5/16-18 .75
Table 3 - Shaft End threaded Holes - Inches
H7H6
H3 (Standard Position)
V6*V5
H8
Standard mounting position is H3. All reducers will be filled to this level, unless otherwise specified.
**Not Recommended
Figure 1 - Reducer Mounting Positions