Operation Manual
15
Technische Daten
Model GZTA 2155X GZTA 2255X GZTA 4125X
Typ
2 Kanal Class A/B 2 Kanal Class A/B 4 Kanal Class A/B
RMS Power @ 4 Ω
CEA Standard CEA-2006-A
2 x 100 W (1% THD+N) 2 x 150 W (1% THD+N) 4 x 90 W (1% THD+N)
RMS Power @ 2 Ω
CEA Standard CEA-2006-A
2 x 150 W (1% THD+N) 2 x 250 W (1% THD+N) 4 x 130 W (1% THD+N)
RMS Power @ 4Ω Gebrückt
CEA Standard CEA-2006-A
1 x 300 W (1% THD+N)
1 x 400 W (10% THD+N)
1 x 500 W (1% THD+N)
1 x 600 W (10% THD+N)
2 x 260 W (1% THD+N)
2 x 320 W (10% THD+N)
Dämpfungsfaktor
> 100
Signal to noise Ratio
> 70 dB
Tiefpass Weiche
40 Hz – 4000 Hz
Hochpass Weiche
5 Hz – 500 Hz
Bandpass Weiche
5 Hz – 4000 Hz
Bass boost
0 ~ +12 dB (45 Hz) 0 ~ +12 dB (45 Hz)
0 ~ +12 dB (45 Hz)
(CH 3 & 4)
Frequenzgang
5 Hz – 38 KHz
(± 1 dB)
Eingangsempfindlichkeit
200 mV – 9 V
(± 5%)
THD
< 0,08 % < 0,08 % < 0,09 %
Bass-Pegelfernbedienung
9
Sicherung
2 x 20A 2 x 30A 2 x 35A
A
bmessun
g
en
B x H x L mm
232 x 49 x 230 332 x 49 x 230 332 x 49 x 230
Abmessungen
B x H x L inch
9.13“ x 1.93“ x 9.06“ 13.07“ x 1.93“ x 9.06“ 13.07“ x 1.93“ x 9.06“
16
Wenn irgendetwas nicht funktioniert
Problem Kontrolle Hilfe
Kein Ton Leuchtet die PWR LED? Sicherung prüfen
Remote Kabel prüfen
+12 Volt prüfen
Masse prüfen
Leuchtet die PROT LED? Kurzschluss am Lautsprecher
Gerät überhitzt
Gerät defekt
V
erstärker
schaltet nicht ein
Keine Stromzufuhr Sicherung prüfen
+12Volt prüfen
Masse prüfen
Keine Spannung am Remote Remote am Radio prüfen
V
erstärker
schaltet bei
Lautstärke ab
Lautsprecherimpedanz prüfen Prüfen Sie, ob der Widerstand am LS Terminal
von 1 Ohm nicht unterschritten wird
Ton fehlt an
einem Kanal
Cinch / Lautsprecherkabel prüfen Kabel/Stecker beschädigt