assembly Instructions

2
GB
Safety notes
In the case of damage to the external transformer
connection cable, this must be replaced by a
qualified electrician in order to prevent a hazard.
Installation is only possible in frost-free rooms.
The control electronics are only suitable for indoor use.
The voltage supply must be separately switchable.
•Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Technical data
Supply voltage 230 V AC
(transformer 230 V AC/12 V AC)
Power consumption 4 VA
Detection zone according to Kodak Gray Card,
grey side, 8x10", landscape: 75 cm
Type of protection
- Fitting IP 59K
- Transformer IP 55
Minimum delay (2 – 10 s, adjustable) 7 s
Electrical test data
Software class A
Contamination class 2
Rated surge voltage 2500 V
Temperature of ball impact test 100 °C
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Electrical installation, see fold-out page II.
Electrical installation work must only be
performed by a qualified electrician. This work
must be carried out in accordance with the
regulations to IEC 60364-7-701 (corresponding to
VDE 0100 Part 701) as well as all national and local
regulations.
Only water-resistant round cables with max. outside
diameter of 6.0 to 8.5 mm may be used.
Installation, see fold-out page II.
Operation,
see technical product information, 99.0438.xxx.
Maintenance, see fold-out page III - IV.
• Shut off water supply
• Switch off voltage supply
• Inspect and clean all components and replace if
necessary.
Replacement parts
see fold-out page I (* = special accessories)
,
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Fault / Cause / Remedy
Fault Cause Remedy
No flushing No voltage (LED in electronics not flashing)
Plug-in connector without contact
Detection zone of sensor system set too low
Leather seal dry or damaged
Solenoid valve defective
Filter in solenoid valve blocked
- Switch on power supply or replace transformer
- Attach plug-in connector
- Increase detection zone using remote control
(special accvalveessories 36 407)
- Expand or replace leather seal, see Maintenance
Flushing, see fold-out page IV, Fig. [7] or [8].
- Replace solenoid valve
- Clean filter
Undesired
flushing
Detection zone of sensor system set too
high
- Reduce detection zone using remote control
(special accessories 36 407)
Flow volume too
low
Solenoid valve defective
Leather seal damaged
- Replace solenoid valve
- Replace leather seal, see fold-out page IV, Fig. [8].
Flow volume too
high
Piston nozzle blocked
Leather seal damaged
- Clean piston nozzle, see fold-out page IV, Fig. [6].
- Replace leather seal, see fold-out page IV, Fig. [8].
Water flowing
continuously
Piston nozzle blocked
Leather seal damaged
Solenoid valve defective
- Clean piston nozzle, see fold-out page IV, Fig. [6].
- Replace leather seal, see fold-out page IV, Fig. [8].
- Replace solenoid valve
Water discharge at
relief valve
Relief valve defective - Replace relief valve, see fold-out page IV, Fig. [9].