Installation & Assembly

4
English
Installation Type #1 and Type #2
Attention for type #1
If both rough-in outlets are used, you have to install a spout
with diverter. If only the lower rough-in outlet is used, you
have to install a spout without diverter.
Installation
1. Install control unit and secure with screws, see Fig. [5].
2. Close water flow by turning the yoke. The mark (A) must be
on top, see Fig. [6].
3. Open the hot and cold integrated service stops, see Fig. [6].
4. While installation observe the right mounting position.
5. For installation of handle parts after adjustment, see
Figs. [7] and [8].
If the thermostat has been installed at too great a depth,
this can be adjusted by 27mm or 1 1/16“ with an extension set
(see Page II, ref. No. 47 889).
Adjustment
Temperature setting, see Fig. [9].
Before the mixer is put into service, if the mixed water
temperature measured at the point of discharge varies from
the specified temperature set on the thermostat handle.
After any maintenance operation on the thermostatic
cartridge.
Valve is closed with lever (B) in vertical position:
Open volume control by turning the lever (B).
1. Measure the temperature of the water emerging with a
thermometer.
2. Turn regulation nut (C) until the water emerging has reached
a temperature of 38 °C or 100 °F.
Reversed union (hot on right - cold on left). Replace
thermostatic cartridge, special cartridge for service is:
Ref. No.: 47 175 (1/2") (see Page II).