Installation & Assembly
3
English
General Application
These trims are for use with the GrohFlex
TM
universal rough-in
valve.
Planning of piping is done at the time of the rough installation.
3 different types of thermostat mixers are possible.
Observe the possible combinations, see Pages 1 and 2.
Specification
• Integral service stops
• Flow pressure:
- min 1 bar or 14.5 psi
- recommended 1-5 bar or 14.5 – 72.5 psi
greater than 5 bar or 72.5 psi, fit pressure reducing valve
• Max. operating pressure 8.5 bar or 125 psi
• Max. test pressure 34.5 bar or 500 psi
• Flow rates at 3 bar or 45 psi
- Type #1 (19 935) and Type #2 (19 947)
bottom outlet 24 l/min or 6,3 gpm
top outlet 12 l/min or 3,2 gpm
- Type #3 (19 940) 51 l/min or 14 gpm
• Temperature
- max. (hot water inlet) 70 °C or 158 °F
• Water connection: cold - RH
hot - LH
General preparation
1. Cut of the excess blue box material, see Fig. [1].
2. Seal the rough-in valve, see Fig. [2].
3. Close the integrated service stops, see Fig. [3].
4. Remove flush cap, see Fig. [4].
1
2
4
3