Installation

2
English
General Application
These Pressure Balance Valves are for use with GrohFlex
TM
universal rough-in valve.
Planing of piping is done at the time of the rough installation.
2 different types of PBVs are possible.
Observe the possible combinations, see Page 1.
Specification
Concealed single handle pressure balancing valve for tub
and shower
Integral service stops
Integral check valves prevent cross flow
Pressure balanced diaphragm cartridge automatically
adjusts to inlet pressure fluctuations
Cartridge restricts hot water supply if the cold pressure fails,
to prevent scalding
Flow pressure:
- min 1 bar or 14.5 psi
- recommended 1-5 bar or 14.5 – 72.5 psi
If greater than 5 bar or 72.5 psi, fit pressure reducing valve
Max. operating pressure 8.5 bar or 125 psi
Max. test pressure 34.5 bar or 500 psi
Flow rates at 3 bar or 45 psi
- Type #1 19 880 23 l/min or 6,1 gpm
- Type #2 19 881
bottom outlet 20 l/min or 5,3 gpm
top outlet 11 l/min or 2,9 gpm
Temperature
- max. (hot water inlet) 80 °C or 180 °F
- The handle rotation stop may be used to limit the maximum
temperature. The maximum temperature will be reached
when the handle is turned in a counter-clockwise direction.
Back-to-back installation is possible by reversing the
pressure balancing cartridge.
Water connection: cold - RH
hot - LH
General preparation
1. Cut of the excess blue box material, see fig. [1].
2. Seal the rough-in valve, see fig. [2].
3. Close the integrated service stops, see fig. [3].
4. Remove flush cap, see fig. [4].
3
1
2
4