user manual

Model G0756 (Mfg. Since 2/13)
-37-
Replacing Lamp
Bulb
The work lamp bulb in this machine is a 24V 25W
two pronged halogen bulb. The replacement part
number for the bulb is P0756418-1.
To replace the bulb in the work lamp:
1. DISCONNECT MACHINE FROM POWER!
2. Using a Phillips head screwdriver, remove
the three screws that hold the work lamp
cover in place.
3. Remove the bulb (see Figure 41).
Figure 41. Work lamp bulb replacement.
Torque Limiter
The torque limiter regulates how much torque
is applied to the drive shaft of the drill press to
prevent the machine from mechanical overload. It
was adjusted at the factory according to the maxi-
mum axial load.
Eventual wear on the limiter discs may require
compensatory adjustment to the torque limiter.
To adjust the torque limiter:
1. DISCONNECT MACHINE FROM POWER!
2. Remove the two cap screws that hold the
plastic cover on the side of the headstock.
3. Rotate the spindle by hand until the set screw
on the torque limiter is visible (see Figure
42).
Figure 42. Torque limiter and set screw.
Set Screw
Torque Limiter
4. Insert the new bulb and replace the work
lamp cover.
Overtightening can break the torque limiter.
Make less than quarter turn adjustments at
one time.
4. Turn the set screw less than a quarter of a
turn using a 4mm hex wrench. One small
adjustment should compensate for any wear
on the limiter disc.