User Manual

9
2. Installation Planning and Service Wiring
WARNING: Disconnect the power supply to the charging station
before installing or adjusting the charging station. Failure to do so may
result in physical injury or damage to the power supply system and the
charging station.
CAUTION: To reduce the risk of fire, connect only to a circuit provided
with the minimum branch circuit overcurrent protection requirements
in accordance with the National Electrical Code ANSI/NFPA 7- and the
Canadian Electrical Safety Code, Part 1, C22.1. If you are unsure if
your circuit meets these requirements consult a licensed electrician.
2.1 Electrical Source Requirements
Prior to using Grizzl-E Mini ensure the electrical source that can support the following Input
Requirements for the Charging Station Per local Electrical Safety Code requirements:
208-240VAC 16A-40A or 110-120VAC 7A-12A Dedicated Circuit
A Double Pole Circuit Breaker of the circuit rating must be used.
Requirements govern that only 80% of the circuit rated load may be utilized.
The Charging Stations can connect a Standard NEMA 14-50 Receptacle, or the provided
adapters can be used.
Caution: Grizzl-E Mini must use the original NEMA 14-50 plug. Do not
attempt to disassemble unit to hardwire or change the plug. Doing so
will void the warranty.