User Manual

5
Product Specications
Description Specications
Model Numbers GRM-14-24-P
Connector EVSE Level SAE J1772; AC Level 2
Electrical Circuit / Input Power
Requirements
Dedicated Single Phase 208-240VAC 50/60 Hz. Branch
Breaker: Double pole
OR
Dedicated Single Phase 110-120VAC 50/60 Hz.
Maximum Output Rating 40A; 9.60kW with 50A Circuit Rating
Alternate Adjustable
Output Ratings
240V Outlet
39A; 9.36kW - 7A; 1.9kW
120V Outlet
12A; 1.44kW - 7A; 0.84kW
Input Power Connection Plug in NEMA 14-50
Installation Rating NEMA 4, Indoor/Outdoor Rated
Operational Ratings Temperature -22F to 122F (-30C to 50C)
Humidity: 95% non-condensing
Overall Dimensions Length: 175mm (6.9in)
Width: 80mm (3.1in)
Height: 60mm (2.4in)
Display and Indicators LED Charge Status Indicator
(Amperage Setting, Ready/Charging, Charging Fault)
Charge Cable Length 24ft (7.3m)