User Manual
Table Of Contents
- 1. Introduction and Unpacking
- 2. Installation Planning and Service Wiring
- 3. Maximum Current Output
- 4. Mounting Bracket
- 5. EasyEvPlug Holster and Cable Management System
- 6. Charging Status Indicators and Buzzers
- 7. Grizzl-E Mini Smart Features
- 8. Operation
- 9. General Product Care and Use
- 10. Warranty and Return Policy
17
6.3 Self-Monitoring and Recovery (Auto Restart)
When a charging session is interrupted due to a temporary error condition, it will
automatically restart charging when the cause of the temporary error condition returns to
normal. The status indicator lights remain flashing RED, with the number of flashes indicating
the error condition, until the error condition is resolved.
• All error conditions can Self-Recover if the error condition is cleared.
• The charging session will be stopped when the error condition occurs. The charger will
self-monitor the error condition. The charger will automatically reset if the error condition
is cleared in 60 seconds. If the error condition is not cleared the charger will continue to
display a RED error light.
• If the error condition occurs within 5 seconds of the start of a charging session a
permanent fault will trigger.
6.2 LED Fault Indicator
When Grizzl-E Mini experiences an error, the red light will ash, and the buzzer will beep a
specic number of times. The cycle will pause for 1 second and repeat. The number of red
ashes and beeps indicates the type of fault:
LED Indicator # of Flashes Error Description
Red Flashing 1 Lost ground - AC Line1
Red Flashing 2 GFCI High Leakage
Red Flashing 3 Relay is stuck
Red Flashing 4 GFCI Low Leakage
Red Flashing 5 High temperature of the module
Red Flashing 6 High temperature of the relay-
Red Flashing 7 Pilot state is Status E
Red Flashing 8 Pilot state is Status F
Red Flashing 9 Diode error
Red Flashing 10 Over Current
Red Flashing 12 Application Error