User Manual

13
4. Adjust the DIP Switches to 40A, 32A, 24A, or 16Ausing the following combination of DIP
Switch Settings:
Maximum Current Output
Switch 1 Switch 2
Switch 3
Switch 4
DIP Switch Setting
40A Maximum Current Output
(Factory Default Setting)
DOWN UP UP
UP
32A Maximum Current Output
DOWN
UP
UP
DOWN
24A Maximum Current Output
DOWN DOWN
UP UP
16A Maximum Current Output
UP
DOWN DOWN DOWN
Once the DIP Switch Setting is adjusted, reassemble the charging station. Reinstall the top
cover to the charging station using the following torque force to secure the 4 cover screws:
16 kgf-cm
13.88 lb-in PH2
TorqueScrew