2.2 Grounding Instructions
The charging station must be implemented equipment grounding through a permanent
wiring system or an equipment grounding conductor. Use a cable with a dedicated grounding
conductor connected to the equipment ground terminal block.
2.3 GFCI
The Charger is equipped with GFCI. Additional downstream GFCI is not required.
In locations where GFCI at the outlet is mandated by code, the charger will not experience
adverse effects.
2.4 Grizzl-E Mini Adaptive Voltage
Grizzl-E Mini can work with either a 208-240V or 110-120V dedicated circuit.
Grizzl-E Mini will automatically detect the outlet power and adjust settings when the input
cable is plugged into the outlet.
Grizzl-E Mini can work with the following adapters:
NEMA 14-50R - NEMA 5-15P. 110-120V VAC. 15A.
NEMA 14-50R - NEMA TT-30P. 208-240 VAC. 30A.
NEMA 14-50R - NEMA 14-30P. 208-240 VAC 30A.
NEMA 14-50R - NEMA 6-50P. 208-240 VAC. Max 50A.