10
2.2 Grounding Instructions
The charging station must be implemented equipment grounding through a permanent
wiring system or an equipment grounding conductor. Use a cable with a dedicated grounding
conductor connected to the equipment ground terminal block.
2.3 GFCI
• The Charger is equipped with GFCI. Additional downstream GFCI is not required.
• In locations where GFCI at the outlet is mandated by code, the charger will not experience
adverse effects.
2.4 Grizzl-E Mini Adaptive Voltage
Grizzl-E Mini can work with either a 208-240V or 110-120V dedicated circuit.
Grizzl-E Mini will automatically detect the outlet power and adjust settings when the input
cable is plugged into the outlet.
Grizzl-E Mini can work with the following adapters:
• NEMA 14-50R - NEMA 5-15P. 110-120V VAC. 15A.
• NEMA 14-50R - NEMA TT-30P. 208-240 VAC. 30A.
• NEMA 14-50R - NEMA 14-30P. 208-240 VAC 30A.
• NEMA 14-50R - NEMA 6-50P. 208-240 VAC. Max 50A.