Tus neeg siv phau ntawv
Table Of Contents
19
6.3 LED Fault Indicator
# of Flashes Error Description Primary Secondary
1 Lost ground - AC Solid Red Flickering Red
2 GFCI High Solid Red Flickering Red
3 Relay is stuck Solid Red Flickering Red
4 GFCI Low Solid Red Flickering Red
5 High temperature of
the module
Solid Red Flickering Red
6 High temperature of
the relay
Solid Red Flickering Red
7 Pilot state is Status E Solid Red Flickering Red
8 Pilot state is Status F Solid Red Flickering Red
9 Diode error Solid Red Flickering Red
10 Over Current Solid Red Flickering Red
11 No connection with
secondary module
Solid Red N/A
12 Application error Solid Red Flickering Red
The number of Red Flashes indicates the charger error:
When a charging session is interrupted due to a temporary error condition, it will
automatically restart charging when the cause of the temporary error condition returns to
normal.
The status indicator lights remain flashing RED, with the number of flashes indicating the
error condition, until the error condition is resolved. All error conditions are able to Self-
Recover if the error condition is cleared.
The charging session will be stopped when the error condition occurs. The charger will self-
monitor the error condition for 60 seconds. If the error condition is cleared the charger will
take an additional 60 seconds to automatically reset. If the error condition is not cleared
the charger will continue to display a RED error light.
If the error condition occurs within 5 seconds of the start of a charging session a
permanent fault will trigger.
6.4 Self-Monitoring and Recovery (Auto Restart)