Coffeemaker User Manual
Page 24 Shuttle Brewers & Airpot/Shuttle Brewers
Troubleshooting (cont.)
Heating Problems
Problem Possible Causes Service Check Remedy
Tank does not heat
• Contactor faulty.
• Heater faulty.
• Control board is faulty.
• Ensure that coil on 
contactor is energized
by ensuring that there 
is proper voltage
between the brown and
white wires attached to
the relay. Check each
side of the contactor
(Line and Load) at each
pole for continuity.
• Check resistance 
across element(s) 
with power conductors
disconnected.
• Check to ensure proper
connection between
connector 5-pin and
control board. Check 
for proper connections 
in all heater control 
circuitry. Check for 
proper connections
between N terminal of
contactor coil and 
terminal block.
• If the contactor coil is 
energized and there is an 
open circuit across any of 
the contactor poles, replace
contactor.
• If resistance is much less than
8 Ohms or much more than 
15 Ohms, replace heater(s).
• If 5-pin connector is securely
attached to control board 
and all connections are 
secure and functioning 
except there is not 120 Vac
across contactor coil terminals, 
replace control board.
Brewing Problems
Problem Possible Causes Service Check Remedy
Brew volume too
large or too small
• Portion selected on
touchpad not correct.
• Timer not set properly.
• Review timer settings
versus portion size.
• Compare timer setting 
to either factory setting 
or initial user setting to
determine if it has 
been changed.
• Adjust timer to desired value or
select different portion size.
• Adjust timer to desired value.