System User Guide / Owners Manual
8
2. Signal Connections
TogglesMaster44.1/48kHzandSlave
Togglesgroup1sampleratemultiplicationfactor
Togglesgroup2sampleratemultiplicationfactor
AES3-out
(follows
AES3-in when
available
and selected,
otherwise
group 2)
AES-in
lockstatus
Inputs
(AES3-in also
for reclocking
purpose)
AES-out
behavior
(thru or
mute)
Impedance
group1
(75 Ohm
or Lo-Z)
Impedance
group2
(75 Ohm
or Lo-Z)
Phaseof
BNC11,
12,13,14
(normal or
180°)
Outputs
group1
Outputs
group2
Indication
offactory
setline
voltage
value
unlock
behavior
(hold or
mute)
3. Operation
Master mode
Theleftmostfrontpanelpushbuttonselectsbetweentwobaseclockrates:44.1kHz
or48kHz.Thetwootherpushbuttonsdeterminetheactualclockfrequencytrans-
mittedacrossthe16BNCoutputs.Theycontrolintwogroups.Group1arechan-
nels1-12.Thesecondpushbuttonsetsthemultiplicationfactorforthisgroupto
1x,2xor4x.Group2arechannels13-16,andtheirmultiplicationfactorissetby
thethirdpushbutton.Setting“48kHz”usingtheleftmostpushbutton,“1x”onthe
middleselectorand“2x”ontherightmostselectorwillsettheclockrateongroup1
BNC’sto48kHzandongroup2BNC’sto96kHz.