Safety data sheet

Page 3/8
Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 30.04.2015 Revision: 30.04.2015Version number 11
Trade name: Griffon Uni 100 XT
(Contd. of page 2)
40.1.5
Fire-extinguishing powder
Carbon dioxide
.
For safety reasons unsuitable extinguishing agents:
Water
Water with full jet
.
5.2 Special hazards arising from the substance or mixture
No further relevant information available.
.
5.3 Advice for firefighters
.
Protective equipment:
Mount respiratory protective device.
.
Additional information
Cool endangered receptacles with water spray.
Collect contaminated fire fighting water separately. It must not enter the sewage
system.
6
Accidental release measures
.
6.1 Personal precautions, protective equipment and emergency procedures
Wear protective equipment. Keep unprotected persons away.
.
6.2 Environmental precautions:
Prevent seepage into sewage system, workpits and cellars.
Do not allow to enter sewers/ surface or ground water.
.
6.3 Methods and material for containment and cleaning up:
Absorb with liquid-binding material (sand, diatomite, acid binders, universal
binders, sawdust).
Dispose contaminated material as waste according to item 13.
Ensure adequate ventilation.
Do not flush with water or aqueous cleansing agents
.
6.4 Reference to other sections
See Section 7 for information on safe handling.
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
7
Handling and storage
.
7.1 Precautions for safe handling
Ensure good ventilation/exhaustion at the workplace.
Prevent formation of aerosols.
Ensure good interior ventilation, especially at floor level. (Fumes are heavier
than air).
.
Information about fire - and explosion protection:
Keep ignition sources away - Do not smoke.
Protect against electrostatic charges.
.
7.2 Conditions for safe storage, including any incompatibilities
.
Storage:
.
Requirements to be met by storerooms and receptacles:
Store in a cool location.
.
Information about storage in one common storage facility:
Not required.
.
Further information about storage conditions:
Keep receptacle tightly sealed.
Store in cool, dry conditions in well sealed receptacles.
.
7.3 Specific end use(s)
No further relevant information available.
*
8
Exposure controls/personal protection
.
Additional information about design of technical facilities:
No further data; see item 7.
(Contd. on page 4)
GB
DPD Declaration
GRIFFON UNI-100 XT FBX 125ML*30 L1
6300545 - GRIFFON UNI-100 XT FBX 125ML*30 L1
www.griffon.eu 3/16