1. Ceiling Systems Handbook.
2. Acoustic Ceilings: Use and Practice.
G. ISO 4611 - Plastics - Determination of the Effects of Exposure to Damp Heat, Water
Spray and Salt Mist.
H. UL - Fire Resistance Directory.
I. USFDA (United States Food and Drug Administration)
1.4 SYSTEM DESCRIPTION
Use this article carefully; restrict statements to describe the combined result (PVC grid) of the
components used to assemble the system. Coordinate with the Regulatory Requirements article below.
A. Ceiling grid covers for use with ceiling grid assembly with a grid face width of [24] [25]
[14] mm ([15/16] [1] [9/16] inch).
B. Ceiling grid covers to not affect the acoustical performance of the ceiling system.
1.5 SUBMITTALS FOR REVIEW
Do not request submittals if drawings sufficiently describe the products of this section or if proprietary
specifying techniques are used. Include a requirement for shop drawings only when special project
conditions exist or when reflected ceiling plans are not provided on the working drawings.
A. Section 01 33 00: Submission procedures.
B. Shop Drawings: Indicate grid layout and related dimensioning, junctions with other
work, interrelation of mechanical and electrical items related to system and [________].
C. Product Data: Provide data on PVC ceiling grid covers components and accessories.
Include the following paragraph for submission of physical samples for selection of finish, colour, surface
texture, etc.
D. Samples: Submit [two] [____] samples each, [200] [____] mm ([8] [____] inches) long,
of grid covers.
1.6 SUBMITTALS FOR INFORMATION
The following submittals are informational; responsive action by the Consultant is not required.
A. Section 01 33 00: Submission procedures.
B. Manufacturer's Installation Instructions: Indicate special procedures, perimeter
conditions requiring special attention, and [________].
1.7 QUALITY ASSURANCE
A. Conform to CISCA requirements.
B. Grid Installer: Company specializing in installing the Products specified in this section,
authorized or certified in writing by the product manufacturer.