6 Installation and commissioning
6.1 Installation of the solenoid valve
- Lock water feed lines.
- Screw the valve into the water connection respectively to the pipe.
Use suitable sealing!
- Check leak tightness by turning on the water supply.
In case of leakage check sealing areas and if installation was carried out correctly. In case of doubt install once
again.
Hint for commissioning: The solenoid valve will only be opened if the control unit has been turned on.
6.2 Installation of the control unit and the water sensor
- Make a rule to read the operating and maintenance advices before starting up the device.
- Use bail to hang the device on desired place, align the device. Remove the protective film from the adhesive
tape at the device’s back and press on the device for locating the device.
- Place the water sensor and fixate it when needed.
Please take care that the sensor electrodes do not touch any metallic surfaces, this may cause errors.
- Connect water sensor to the control unit.
- When not already done turn on water supply for the solenoid valve.
- Plug the control unit’s adapter plug into a socket outlet with protective contact.
- Turn on the control unit via power switch and pressing service button at the same time.
A red LED indicates the device is operating and the solenoid valve has opened.
- Check water connection tubes for leakage.
- Connect washing machine resp. dishwasher to the protective contact socket of the control unit.
- FUNCTION TEST: Check the alarm function via bypassing the water sensor electrodes (e.g. via touching both
electrodes).
The device will now start its alarm; the solenoid valve will be closed. Turn off and on the control unit.
! Well done, your GEWAS device is now ready for use !
7 Function
When a water film at the water sensor exceeds 0.5 mm, the control unit will automatically initiate an audible alarm,
will be closing the solenoid valve and will turn off the device connected to the power sockets of the device.
To remove the alarm the control unit has to be turned off.
When the water sensor is disconnected from the device, the alarm will also be initiated.
8 Operating elements
Switch „POWER“
Position 0: GEWAS-control unit is switched off, protective contact socket is powered off, solenoid valve is closed
Position 1: GEWAS-control unit is switched off , monitoring is active, water can flow.
protective contact socket is powered except there is an alarm condition
Button „SERVICE“
In normal operation (no alarm) the valve is operated in a low power mode.
In case of calcification or similar soiling the valve may be locked in position. With the SERVICE button the operation
current can be raised for a short time, which helps a blocked low power valve to operate regular again.