COMPACT CO - MEASURING DEVICE
HIGHLIGHTS:
• 3 display units selectable
(ppm, mg/m³ and % CO Hb)
• Alert at exceeding the maximum
concentration at work (MAK/AGW)
• incl. interface
GCO 100
Product-ID: 600062
CO-measuring device
General:
Carbon monoxide (CO) is created by the combustion of
carbon. Depending on the effectiveness of the combustion
(oxygen supply) and the temperature of the combustion
more or less CO gas is created. The gas is infl ammable
and highly toxic. It is invisible, tasteless and scentless.
Even smallest concentrations are dangerous for
humans!
Therefore a directive exists in Germany, which limits the
maximum concentration of CO gas at work (MAK / AGW)
to 30 ppm.
Application:
• Control of the air quality (e.g. at work place)
•
Checking of heating systems, gas central-heating, replace
• Control of the air at maintenance work
(tunnel, fl ue gas tract, ...)
• Detection of CO in the breath of smoker (% CO Hb)
• Cognition of CO poisoning i.e. at burnt offering
( re ghters, ...)
Speci cations:
Measuring principle:
electrochemical CO measuring cell
Measuring range: 0 ... 1000 ppm CO concentration
Display ranges: 0 ... 1000 ppm CO concentration
0 ... 1250 mg/m³ CO concentration
0 ... 60.0 % CO Hb
(estimation via exhaled breath gas)
Resolution: 1 ppm, 1 mg/m³ or 0.1 % CO Hb
Measuring element: integrated in device, measuring in-
let at front plate, with inner thread
for accessories screw in
Life time: >5 years at proper usage at air
suggested test interval: every 6
months (depending on precision
requirements)
Accuracy: (at range 0 ... 500 ppm)
linearity: < ±5 % of measured value ±1 digit
repeatability: < ±5 % of measured value ±1 digit
Interference: (extract)
sulphur dioxide
nitrogen dioxide
nitric oxide
hydrogen
carbon dioxide
Concentration residence time display
(ppm) (min.) (ppm)
50 600 <1
50 900 -1
50 5 8
100 5 20
5000 5 0
Display: approx. 11 mm high, 4½-digit
LCD-display
Pushbuttons: 3 membrane keys
Nominal temperature:
25 °C
Ambient condition: -10 ... +50 °C, 15 ... 90 % RH
(non condensing)
Storage temperature: -10 ... +50 °C
Serial interface:
Serial interface, direct connection to
RS232 or USB interface of a PC via
electrically isolated interface adapter
Power supply: 9 V-battery as well as additional
d.c. connector for external 10.5
- 12 V direct voltage supply.
(suitable power supply: GNG 10
/ 3000)
Power consumption: <0.25 mA (>1000 operating hours)
Housing: impact-resistant ABS plastic
housing, membrane keyboard,
transparent panel. Front side
IP65, integrated pop-up clip for
table top or suspended use.
Dimensions: 142 x 71 x 26 mm (H x W x D)
Weight: approx. 155 g
Scope of supply: Device, battery, manual
Accessories and spare parts:
ESA 100
Product-ID: 603013
tube-adapter/fl ow diverter to screw in front plates.
ZOT 369
Product-ID: 603094
T-piece
GRV 100
Product-ID: 603093
non return valve
MSK 100
Product-ID: 603012
mouth peace of plastic
GAS 100
Product-ID: 603587
extension set for exhaled air control (consisting of
ESA100, ZOT369, GRV 100 and 5x MSK100)
GZ-10
Product-ID: 603133
test gas cap GCO (for controlled fl ow with test gas)
GZ-02
Product-ID: 603569
gas bottle with 12l test gas: 30 ppm CO
GZ-03
Product-ID: 603123
gas bottle with 12l test gas: 300 ppm CO
GZ-04
Product-ID: 603570
gas valve unit MiniFlo for gas bottles with 12l
GB 9 V
Product-ID: 601115
spare battery 9 V / approx. 300mA/h
GLI 9 V
Product-ID: 601117
Lithium battery 9 V / approx. 1200 mA/h
GKK 3000
Product-ID: 601048
case (275 x 229 x 83 mm) with punched lining
USB 3100 N
Product-ID: 601092
interface converter to USB, electrical isolated
GAM 3000
Product-ID: 601132
switching module for 230 VAC/10 A
FUNCTIONS:
ESA 100
ZOT 369
GRV 100MSK 100
GOX 100
Product-ID: 600142
for universal applications
General:
• 1-button calibration
• Automatic power-off
• Min-/max- value memory
• Incl. sensor GOEL 370
Note: not for under water use (Rebreathers)
GOX 100T
Product-ID: 600157
for diving applications
General:
• 1-button calibration
• MOD-Display (Maximum Operating Depth)
• HOLD function
• Incl. sensor GOEL 370
Note: not for under water use (Rebreathers)
Speci cations:
Measuring range: 0.0 ... 100.0 % O
2
Accuracy typ.: ±0.1 % O
2
±1 digit, calibrated
device (range from 15 ... 40 % O
2
)
MOD (GOX 100T): 0 ... 100 m / 0 ... 199 ft
Sensor Connection: 0.7 m jack-connector cable
Sensor Oxygen-partial pressure probe,
mounted in external sensor
housing
Warranty: 12 months
Working pressure: 0.5 ... 2.0 bar abs.
Over- /under-
pressure:
max. 0.25 bar
(pressure difference)
Working
temperature:
0 ... 45 °C (sensor),
-20 ... +50 °C (device)
Relative humidity: 0 ... 95 % RH
Power supply: 9 V battery
Power consumption: approx. 120 µA (over 2500 h)
Display: 3½-digit, 13 mm high LCD-display
Housing: ABS-enclosure, front side IP65
Dimensions: approx. 106 x 67 x 30 mm
(H x W x D)
Weight: approx. 185 g
Scope of supply: Device incl. sensor, tube-adaper,
t-piece, battery
Variants:
GOX 100-LACK
Product-ID: 602047
with encapsulated PC board
(for applications where condensation is possible)
GOX 100-T-LACK
Product-ID: 604660
with encapsulated PC board
(for applications where condensation is possible)
COMPACT AIR OXYGEN
MEASURING DEVICE
FUNCTIONS:
FOR DIVING
APPLICATIONS
THE DEVICE IS ONLY INTENDED FOR CONTROL
PURPOSES FOR THESE APPLICATIONS. IT IS NOT
A REPLACEMENT FOR A MONITORING DEVICE
SUBJECT TO AUTHORISATION!