Use and Care Manual
9
MAINTENANCE
DISCONNECT PUREHEAT 3-IN-1 FROM THE OUTLET BEFORE ANY MAINTENANCE OR CLEANING.
Filling the Humidier
1. Open the HUMIDIFIER TANK CHAMBER (Open the door on the right side of the unit).
2. Slide the HUMIDIFIER TRAY out and remove the HUMIDIFIER WATER BOTTLE
3. Fill the HUMIDIFIER WATER BOTTLE with tap water and replace in HUMIDIFIER TRAY.
Once the water has lled the tray, rell the HUMIDIFIER WATER BOTTLE a second
time, replace in HUMIDIFIER TRAY.
4. Slide the HUMIDIFIER TRAY back into the HUMIDIFIER TANK CHAMBER.
5. Close the HUMIDIFIER TANK CHAMBER.
Replacing the PCO Cell
After some time the “Replace UV BULB” indicator may appear on your LCD SCREEN.
This indicates that you need to replace your PCO Cell. You may purchase a
replacement PCO Cell through your GreenTech Environmental Authorized Distributor.
If your distributor is not available, please visit www.GreenTechEnv.com to contact us
regarding ordering a PCO Cell directly.
1. Remove the FILTER ASSEMBLY by following steps 1 through 3 of “Cleaning the Filter”.
2. Unplug the old PCO Cell by squeezing and disengaging the electrical adapter in the
lower right hand region of the rear of the unit.
3. Unscrew both of the plastic coated brass thumbscrews from their posts. Set the
thumbscrews aside where you will not misplace them.
4. Slide the old PCO Cell straight out of the rear of the unit.
5. Slide the new PCO Cell straight into it’s place in the rear of the unit.
6. Screw both thumbscrews back onto their post until snug.
7. Connect the new PCO Cell by plugging in the electrical adapter to it’s socket until it
clicks into place.
8. Replace the FILTER ASSEMBLY by following steps 7 through 9 of “Cleaning the Filter”.