Typical Measurements and Accuracy (cont’d)
Ω
Resistance 
Measurement
SELECT
Continuity Check
Resistance
Range Accuracy
600.0 Ω ± (1.0% + 0.5 Ω)
6.000 kΩ ± (1.0% + 0.005 kΩ)
60.00 kΩ ± (1.0% + 0.05 kΩ)
Open Circuit Voltage:  1.0 VDC
Continuity
Tone Threshold:  Between 10 Ω and 250 Ω
Response Time:  Approximately 32 ms
Capacitance 
Measurement
Capacitance (CM-860, CM-960, 
CMH-600, and CMI-600 only)
Range Accuracy*
200.0 μF ± (2.0% + 0.4 μF)
2500 μF ± (2.0% + 4 μF)
  * For film capacitors (capacitors with 
negligible dielectric absorption).
Note:  For polarized capacitors, attach red 
probe to positive terminal and black probe to 
negative terminal of capacitor.