Rev 20190828 We Power Your World! Owner’s Manual of Generator for GN5250DW Green-Power America,LLC
Products Service Green-Power America LLC thanks you for choosing a Green-Power America product. egister your product within 10 days of purchase to ensure that you receive service. egistering your product 1. You have a record of the product purchase, 2. Customer Service can Be serve you on Warranty related issues, 3. You can register your product in one ways as follow 1: o to the website at www.green-poweramerica.
5250W D ual F uel Generator Topi c Page Limited Warrant y 3 Sa fet y G u i d e l i n e s 5 G e n e r a l Pr e c a u t i o n s 6 Assembly and Installation 15 Operation 18 Inspection,Cleaning,Maintenance and Storage 23 Speci fications 30 General Par ts Listing 31 GREEN-POWER AMERICA,LLC(HEREINAFTER IN SHORT “GREEN-POWER” OR “GPA” ) 2
Owner’s Manual Green-Power America (GPA) Version 2018-1 1st Revise WARRANTY POLICY -- GENERATOR Green-Power America, LLC (GPA) Two(2)-YEAR LIMITED WARRANTY or One(1)-YEAR LIMITED WARRANTY Green-Power America, LLC (GPA) provides Two(2)-Year or One(1)-Year (GPD1500 and GN1750D) limited factory warranty once consumers buy the water pump from GPA or any of GPA partners in the United Sates.
250W D ual Fuel Generator Green-Power America (GPA) Version 2018-1 1st Revise keep it for future reference. Repairs or replacements without prior authorization, or at an unauthorized repair facility, will not be covered by this warranty.
Owner’s Manual Green-Power America (GPA) Version 2018-1 1st Revise –Accessory parts such as starting batteries, tools and storage covers. –Failures due to acts of God and other force majeure events which beyond the manufacturer's control. –Problems caused by parts that are not original Green-Power America (GPA) parts. When applicable, this warranty does not apply to products used for prime power in place of a utility.
5250W D ual Fuel Generator Green-Power Green-Power Green-Power Green-Power please call specified toll free number.
Owner’s Manual Green-Power Green-Pow 7
5250W D ual Fuel Generator Safety Guidelines - Definitions This manual contains important information that you need to know and understand in order to protect YOUR SAFETY and to PREVENT EQUIPMENT PROBLEMS. The following symbols help you recognize this information. Please read the manual and pay attention to these sections. Save These Important Safety Instructions! Read and understand all of these safety instructions. Be sure to retain them for future use.
Owner’s Manual General Precautions WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SEVERE INJURY OR DEATH. CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS CAN ALSO RESULT IN DAMAGE TO THE TOOL AND/OR THE ITEM YOU ARE WORKING ON. DANGER CARBON MONOXIDE Using a generator indoors WILL KILL YOU IN MINUTES. Generator exhaust contains high levels of carbon monoxide (CO), a poisonous gas you cannot see or smell. If you can smell the generator exhaust, you are breathing CO.
5250W D ual Fuel Generator General Precautions (cont’d) Gasoline and Oil (cont’d) • Fuel or oil spills must be cleaned up immediately. Dispose of fluids and cleaning materials as per any local, state, or federal codes and regulations. Store oily rags in a covered metal container. • Never store fuel or other flammable materials near the generator. • Do not smoke, or allow sparks, flames or other sources of ignition around the engine and fuel tank. Fuel vapors are explosive.
Owner’s Manual General Precautions (cont’d) Work Area • Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents. • Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Generators create sparks which may ignite the dust or fumes. • Keep bystanders, children, and visitors away while operating a generator. Provide barriers or shields as needed.
5250W D ual Fuel Generator General Precautions (cont’d) Electrical Safety (cont’d) • All connections and conduits from the generator to the load must only be installed by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable. • The generator must be earth-grounded for fixed installations in accordance with all relevant electrical codes and standards before operation.
Owner’s Manual General Precautions (cont’d) Personal Safety (cont’d) • Avoid accidental starting. Make sure the power switch is in its “OFF” position, and disconnect the spark plug wire when not in use. • Remove adjusting keys or wrenches before turning the generator on. A wrench or a key that is left attached to a rotating part of the generator may result in personal injury. • Do not overreach. Keep proper footing and balance at all times. • Use safety equipment. Always wear eye protection.
5250W D ual Fuel Generator General Precautions (cont’d) Servicing Maintain labels and name plates on the generator and engine. These carry important information. If unreadable or missing, contact our service center toll free immediately for a replacement. Generator service must be performed only qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury. When servicing a generator, use only identical replacement parts.
Owner’s Manual General Precautions (cont’d) Installation (cont’d) • If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. It should not be run outdoors without protection to the generator and wiring conduit. • The generator might weigh over 100 lbs Two or more people should assist when moving or lifting this product. Never lift the generator using the engine or alternator lifting lugs.
5250W D ual Fuel Generator General Precautions (cont’d) Mechanical (cont’d) • Do not operate the generator with safety guards removed. While the generator is running, do not attempt to reach around the safety guard for maintenance or any other reason. • Keep hands, arms, long hair, loose clothing, and jewelry away from moving parts. Be aware that when engine parts are moving fast they cannot be seen clearly. • Keep access doors on enclosures closed and locked when access is not required.
Owner’s Manual General Precautions (cont’d) Extension Cord If an extension cord (not included) is used, make sure to use only UL approved cords having the correct gauge and length according to the following table: Nameplate Amps (@ full load) Cord Lengths 0 ft.- 50 ft. 50 ft.-100 ft. 100 ft.-150 ft. 150 ft.-200 ft. 0-5 5.1 - 8 16 AWG 16 AWG 16 AWG 14 AWG 12 AWG 10 AWG 12 AWG - 8.1 - 12 12.
5250W D ual Fuel Generator Assembly and Installation Unpacking 1. Remove the generator and loose parts box from the carton. 2. Compare the Hardware Kit included with the inventory list below. Loose Parts (Wheel kit and handle) Check all loose parts against the following list. Contact your dealer toll free at 888.834.4218 if any of the loose parts shown are not included with your generator Hardware Check: Your Hardware Kit should include: 1) Two Handles with bolts, pin .Fig 1 2) Two axle shaft with nuts.
Owner’s Manual Installation NOTE: PRIOR TO POWERING TOOLS AND EQUIPMENT MAKE SURE THE GENERATOR’S RATED VOLTAGE, WATTAGE AND AMPERAGE CAPACITY IS ADEQUATE TO SUPPLY ALL ELECTRICAL LOADS THAT THE UNIT WILL POWER. IF POWERING EXCEEDS THE GENERATOR’S CAPACITY, IT MAY BE NECESSARY TO GROUP ONE OR MORE OF THE TOOLS AND/OR EQUIPMENT FOR CONNECTION TO A SEPARATE GENERATOR. Electrical and other permits may be required for the installation of emergency power systems.
5250W D ual Fuel Generator Installation (cont’d) Supporting and Mounting Mount the generator on a concrete slab capable of supporting the weight of the generator. The slab must extend on all sides beyond the frame by at least one foot. Contact a cement contractor for slab specifications if necessary. Attach the frame to the concrete slab using 3/8” diameter expansion anchor bolts (not supplied).
Owner’s Manual Operation NOTE: THE PARTS LISTED ABOVE ARE HELPFUL FOR LOCATING THE CONTROLS MENTIONED BELOW. Before Starting the Generator CAUTION: PRIOR TO FIRST USING THE GENERATOR, THE ENGINE MUST BE FILLED WITH HIGH QUALITY SAE 10W-30 GRADE ENGINE OIL. TO DO SO, UNSCREW AND REMOVE THE ENGINE’S OIL DIPSTICK LOCATED AT THE BOTTOM OF THE ENGINE CRANKCASE. FILL THE ENGINE CRANKCASE UNTIL THE OIL LEVEL IS LEVEL WITH THE UPPER MARKED LINE ON THE DIPSTICK. THEN SCREW THE DIPSTICK BACK INTO THE OIL FILL HOLE.
5250W D ual Fuel Generator Operation (cont’d) Starting ON 1.Select Fuel Source: FOR GASOLINE: ON O FF GAS a.Switch the gasoline valve to ON position (Fig 8) b.Turn the Fuel Select Switch point to GAS (Fig 9) Fig 9 Fig 8 FOR LPG/PROPANE: a.Make sure the LPG hose is safely secured from the generator to the tank. b.Switch the gasoline valve to OFF position (Fig 10) c.Turn the Fuel Select Switch point to LPG (Fig 11) d.Fully open the propane tank valve.
Owner’s Manual Operation (cont’d) STOPPING THE GENERATOR ON O FF 1.Remove all connections from the control panel receptacles 2. Allow the generator to run at “no load” to reduce and stabilize engine and alternator temperatures. Fig 11 3. If you operate with gas, switch the gasoline valve to OFF position(Fig 11); Or if you operate with propane, shut -off the propane tank valve(Fig 14). 4.
5250W D ual Fuel Generator Operation (cont’d) Powering 120/240Volt AC Tools And Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage capacity is adequate to supply all electrical loads that the unit will power. If powering exceeds the generator’s capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate generator.
Owner’s Manual Operation (cont’d) Powering 12 Volt DC tools and Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage capacity (12V DC) is adequate to supply all electrical loads that the unit will power. If powering exceeds the generator’s capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate generator. 2. Connect the power cord of a 12 VDC powered tool or equipment to the DC Terminals.
5250W D ual Fuel Generator Inspection, Cleaning, and Maintenance WARNING! ALWAYS MAKE SURE THE ENGINE POWER SWITCH IS IN ITS “OFF” POSITION. DISCONNECT THE SPARK PLUG WIRE FROM THE ENGINE. AND ALLOW SUFFICIENT TIME FOR THE ENGINE AND GENERATOR TO COMPLETELY COOL BEFORE PERFORMING ANY INSPECTIONS, MAINTENANCE, OR CLEANING. Spark Plug Maintenance In order to service the spark plug, you will need a spark plug wrench (commercially available).
Owner’s Manual Fuel Sediment Cup Cleaning(If It Is Applied) The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. 1. Turn the fuel valve to the OFF position. Remove the sediment c up, and O-ring. (Fig 17) 2. Clean the sediment cup, and O-ring, in nonflammable or high flash point solvent. 3. Reinstall O-ring, and sediment cup. 4. Turn the fuel valve ON and check for leaks.
5250W D ual Fuel Generator Maintenance Guide Periodic maintenance and adjustment is necessary to keep the generator in good operating condition. WARNING! Exhaust gas contains poisonous carbon monoxide. Shut off the engine before performing any maintenance. If the engine must be run, make sure the areas is well ventilated. • Before each use, inspect the generator.
Owner’s Manual Air cleaner Maintenance A dirty air cleaner will restrict air flow to the carburetor. lower generator output power and deteriorate the engine emission To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. WARNING! Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion. Use only soapy water or nonflammable solvent.
5250W D ual Fuel Generator 30
Owner’s Manual Transporting/Storage 1.Drain the carburetor by loosengine the drain screw.Drain the gasoline into asuitable container.(017) ! WARNING Gasoline is extremely flammable and is explosive under certain conditions Perform this task in a well ventilated area with the engine stopped.Do not smoke or allow flames or spartks In the area during this producedure. (Change the engine oil) 017 2.Change the engine oil. 2.1 Drain the used oil while the engine is warm.
5250W D ual Fuel Generator Wiring Diagram for GN5250DW G DC PROTECTOR R DC WINDING W R W B BR 32
Owner’s M anual Specifications AC electrical Current Output 16A Running Watts 4250W(GAS)/3800(Propane) Starting Watts 5250W(GAS)/4750(Propane) Two 120V 20A NEMA 5-20 Receptacle one 120V/240V 30A NEMA L14-30R Receptacle Outlet DC electrical Outlet 12V@8.3A Gasoline engine Type 4-cycle OHV air-cool ed recoil start Displacement 223cc 20.3 fl oz (0.6 L) Oil c apacity EPA approved yes Fuel Type Unleaded g asoline Capacity 4 gallons Running t ime 11.5 hours (approx.
5250W D ual Fuel Generator LCT engine parts cylinder head system assy. 4 GPA Parts No. LCT Parts No. Description Qty PGH40025 CYLINDER HEAD COMP. GPG4000-A-02 PGH49028 FLANGE BOLT (M8X58) 1 4 GPG4000-A-03 PGH44726 SPAR K PLUG 1 GPG4000-A-04 PGH40075 CYLINDER HEAD SEALING PAD 1 GPG4000-A-05 PGH40653 HEAD COVER COMP.
5250W D ual Fuel Generator LCT engine parts Cylinder barrel Qty LCT Parts No. Description GPD5000-B-01 PGH48101 CRANK CASE 1 GPD5000-B-02 PGH44760 OIL LEVEL SWITCH ASSY. 1 GPG4000-B-03 PGH45125 GOVERNOR GEAR ASSY.
5250W D ual Fuel Generator LCT engine parts Crankcase cover system assy. GPA Parts No. LCT Parts No.
5250W D ual Fuel Generator LCT engine parts Crankshaft system assy. GPA Parts No. LCT Parts No. Description Qty GPD5000-D-01 PGH48207 CRANKSHAFT COMP.
5250W D ual Fuel Generator LCT engine parts Piston and connecting rod system assy. Description Qty GPA Parts No. LCT Parts No.
5250W D ual Fuel Generator LCT engine parts Valve Train Assembly 12 10 11 13 15 GPA Parts No. LCT Parts No.
5250W D ual Fuel Generator LCT engine parts Recoil Starter Assy. 11 10 9 7 8 5 6 2 4 2 3 2 1 13 12 15 14 . Qty GPA Parts No. LCT Parts No. Description GPG4000-G-01 PGH46050.1.1 ELASTIC CYLINDRICAL PIN 1 GPG4000-G-02 PGH46050.1.2 WASHER ¢10 3 GPG4000-G-03 PGH46050.1.3 PRESSURE SPRING 1 GPG4000-G-04 PGH46050.1.4 SPRING RETAINER 1 GPG4000-G-05 PGH46050.1.5 STARTER RATCHET 2 GPG4000-G-06 PGH46050.1.6 RETURN SPRING 2 GPG4000-G-07 PGH46050.1.
5250W D ual Fuel Generator LCT engine parts Fan cover system assy. 7 7 3 8 GPA Parts No. LCT Parts No. Description Qty GPG4000-H-01 PGH46145 FAN COVER COMP.
5250W D ual Fuel Generator LCT engine parts Carburetor system assy. 2 1 LPG 4 GAS 5 3 6 Qty GPA Parts No. LCT Parts No. Description GN5250-I-01 PGH48509. 1 CARBURETOR ASSY. 1 GPG4000-I-02 PGH44128 CARBURETOR PAPER GASKET 1 GPG4000-I-03 PGH44150 CARBURETOR INSULATING PLATE 1 GPG4000-I-04 PGH44203 INTAKE PIPE GASKET 1 GN5250-I-05 PGH48509. 2 FUEL SELECTOR SWITCH 1 GN5250-I-06 PGH48509.
5250W D ual Fuel Generator LCT engine parts Flywheel system assy. 2 3 LCT Parts No. Description Qty GPG4000-J-01 PGH42461 FLYWHEEL 1 GPG4000-J-02 PGH42475 FLYWHEEL NUT (M14X1.5 ) 1 GPG4000-J-03 PGH42500 COOLING FAN 1 GPG4000-J-04 PGH46142 STARTER PULLEY 1 GPA Parts No.
5250W D ual Fuel Generator LCT engine parts Ignition System Assy. Qty GPA Parts No. LCT Parts No. GPG4000 -K-01 PGH44675.2-1 NOISE SUPPERSSOR CAP ASSY 1 GPG4000 -K-02 PGH44675.2-2 IGNITION COIL ASSY 1 GPG4000 -K-03 PGH44675.
5250W D ual Fuel Generator LCT engine parts Control system assy. GPA Parts No. LCT Parts No. GPG4000-M-01 PGH45078 CONTROL UNIT ASSY. 1 GPG4000-M-02 PGH45078-2 CONTROL BASE COMP.
5250W D ual Fuel Generator LCT engine parts Air cleaner 8 GPA Parts No. LCT Parts No. GPG4000-N-01 PGH42160 GPG4000-N-02 PGH42160.2-2 GPG4000-N-03 PGS40003 GPG4000-N-04 PGH42160.2-4 GPG4000-N-05 PGH42160.2-5 GPG4000-N-06 PGH42160.2-1 GPG4000-N-07 PGH44104 GPG4000-N-08 PGS20000-M6 8 DESC RIPTION AIR C LEANER C OV ER C OMP AIR C LEANER ELEMENT.
5250W D ual Fuel Generator Equipment Parts excluded in LCT Engine Muffler System Assy. 5 5 5 5 4 5 3 1 2 GPA Part No. Factory Part No. Descript io n GPD4000-O-01 BGG31005 MUFFLER STAY COMP. 1 GPD4000-O-02 BGS30007 FLANGE BOLT (M8 X 16) 2 GPD5000-O-03 BGG30212 MUFFLER COMP. 1 GPD4000-O-04 BGG31520 MUFF. OUTER PROTECTOR COMP.
5250W D ual Fuel Generator Equipment Parts excluded in LCT Engine 1 Fuel tank system assy. 4 6 5 10 6 11 12 8 9 7 9 GPA Parts No. Factory Parts No. Descript io n Qty GN5250-P-01 BGG21009.1 FUEL FILLER CAP COMP 1 GPG4000 -P-02 BGG21006.2 FUEL FILTER 1 GPG4000 -P-03 BGG20558.1.5-1C FUEL TANK COMP.
5250W D ual Fuel Generator Equipment Parts excluded in LCT Engine Control panel assy. 2 1 8 7 5 9 3 6 4 GPA Parts No. Factory Parts No. Description GPG4000 -Q-01 BGG50200 ENGINE SWITCH ASSY.
5250W D ual Fuel Generator Equipment Parts excluded in LCT Engine Frame Comp ASSY. 1 2 3 GPA Parts No. Factory Parts No. Description R Qty GN5250-R-01 BGG40342 GENERATOR FRAME 1 GPG4000-R-02 BGG61006 BOTTON RUBBER A 4 GPG5000-R-02 BGG50068.
50W D ual Fuel Generator Equipment Parts excluded in LCT Engine Generator. 7 19 11 GPA Parts No. Factory Parts No Description GPD5000-S-01 BGG11903.1.2 STATOR COVER 1 GPD5000-S-02 BGG11903.1.3 STATOR ASSY. 1 GPD5000-S-03 BGG11903.1.4 COOLING FAN 1 GPG4000-S-04 BGG13100 BRUSH ASSY.
5250W D ual Fuel Generator Equipment Parts excluded in LCT Engine Wheel & Hand Assy. 3 3 1 2 4 1 1 4 2 7 5 7 6 9 11 8 9 9 1 5 6 9 10 11 8 T Description GPA Parts No. Factory Parts No. GPG5250-T-01 BGS61001 SPLIT PIN 4 GPG6500-T-02 BGS20006.1.
Distributed by: Green-Power America, LLC www. Green-PowerAmerica.