SDS

1541551-Lithium-ion Battery Pack GMBA6200-25 62V 135Wh
_
_
Page 3 / 13
3. COMPOSITION/INFORMATION ON INGREDIENTS
Substance
Not applicable.
Mixture
Chemical name
Weight-%
Hazardous Material
Information Review Act
registry number (HMIRA
registry #)
Date HMIRA filed and
date exemption granted
(if applicable)
PC
13.4%
-
-
ABS
20.4%
PA6
5.7%
Glass Fiber
2.5%
-
-
TPE
6.3%
-
-
Ni
1.4%
-
-
Iron
10.2%
-
-
Lithium nickel aluminate cobalt oxide
14.9%
-
-
Graphite
8.1%
-
-
Polyvinylidene Fluoride (PVDF)
0.2%
-
-
Ethylene carbonate
1.9%
-
-
Dimethyl carbonate
1.9%
-
-
Lithium hexafluorophosphate (LiPF6)
0.9%
-
-
Copper
6.3%
-
-
Aluminum
2.7%
Carbon black materials
3.2%
4. FIRST AID MEASURES
Description of first aid measures
General advice First aid is upon rupture of sealed battery. Show this safety data sheet to the doctor in
attendance. Immediate medical attention is required. IF exposed or concerned: Get
medical advice/attention.
Inhalation Remove to fresh air. If breathing has stopped, give artificial respiration. Get medical
attention immediately. Do not use mouth-to-mouth method if victim ingested or inhaled
the
substance; give artificial respiration with the aid of a pocket mask equipped with a one-
way valve or other proper respiratory medical device. If breathing is difficult, (trained
personnel should) give oxygen. Delayed pulmonary edema may occur. Get immediate
medical advice/attention.