Material Rate User Manual
411-020B Table of Contents 2014-03-17
92 1625AHD/AHL Table of Contents Great Plains Manufacturing, Inc.
Liquid Fertilizer Rates
Liquid fertilizer planter models (1625AHL) use a
CDS-John Blue
®
piston pump. For pump operation and
pump maintenance refer to the Planter Operator manual
and CDS-John Blue
®
pump manual. The
CDS-John Blue
®
manual is supplied with the planter.
The pump is driven by a ground drive wheel, and
fertilizer rate is independent of seed rate. Fertilizer rate is
set by a pump dial and a sprocket on the ground drive
assembly.
Note: Great Plains recommends checking with your local
Agronomist as soil conditions vary. Soil conditions
in your area may need lesser or more amounts of
fertilizer than represented in these charts. Do not
exceed 112 liters/ha (12 gallons/acre) in any case.
Note: Always lock-up the ground drive when not in use.
Do not operate planter pump when not applying
material. See the planter Operator manual for lock-
up instructions.
Liquid Rate Setting Overview
1. Determine the desired application rate in litres per
hectare or gallons per acre.
2. Install orifice plates appropriate for that rate. See
page 93. Skip this step if using VeriFlow nozzles.
3. Verify that the strainer mesh size is suitable for the
rate. See page 95.
4. Determine the Range sprocket and pump Adjuster
Dial setting required for your rate. See page 96.
Configure the sprocket and dial.
5. At first use, adjust the Relief Valve to the suggest
initial setting. See page 101. Make further
adjustments based on pressure readings afield.
Figure 22
CDS-John Blue
®
Pump
28416