Instruction Manual
www.grayhill.com
Grayhill, Inc.
561 Hillgrove Avenue phone: (708) 354-1040
LaGrange, Illinois 60525 fax: (708) 354-2820
Bulletin 1144
Rev 06/14
DIMENSIONS
3.2
[81,28]
specications subject to change
Vibration, Random ANSI/ASAE EP455
5.15.1
2h each axis @52.4m/s2 RMS overall
acceleration and spectral power density of
2m2/s3 from 50Hz to 2000Hz
Vibration, Sinusoidal ANSI/ASAE EP455
5.15.2
A logarithmic sweep from 10Hz to 2000Hz to
10Hz over a period of 20 minutes for 4 hours
in each of 3 orthogonal axes with amplitude
1.5mm from 10Hz to 40Hz and a constant
acceleration of 35m/s2 RMS from 40Hz to 2KHz
Shock / Crash Safety ANSI/ASAE EP455 5.14 11ms half sine pulse of 490 m/s2 in 3
perpendicular axes
Drop ANSI/ASAE EP455
5.14.2 Level 1
Drop component 400 mm onto a hardwood
benchtop on all practical edges.
MECHANICAL PERFORMANCE
ESD ANSI/ASAE EP455 5.12 Level 1 +/- 25KV
Radiated Immunity EP455 5.16 Level 1
Conducted emissions SAE J1113-41 Level 4
Radiated emissions ISO14982
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS
Maximum load ANSI/ASAE EP455 5.1.1 Level 2
Jump start voltage EP455 5.10.2 36V for 60 minutes; -36V for 60 minutes
Short circuit protection EP455 5.10.4 36V
Reverse polarity
protection
EP455 5.10.3 -36V
Starting prole ISO 16750-2 Level II code C, Level IV code A
Battery-less operation ANSI/ASAE EP455 5.11.3 Level 2
Load dump ISO 7637-2 Test Pulse 5b Us* = 60V
Switching spikes ISO 7637-2 Test Pulse 3a
and 3b
Wire harness inductance ISO 7637-2 Test Pulse 2a
and 2b
Wire harness inductance-
switching
ISO 7637-3 Test Pulse
a and b
Inductive load pulse ANSI/ASAE EP455 5.11.4
Mutual coupling ANSI/ASAE EP455 5.11.6
Level 2
Alternator eld decay ANSI/ASAE EP455 5.11.2
ELECTRICAL PERFORMANCE SPECIFICATIONS
CONTACT GRAYHILL FOR CUSTOM OPTIONS
PART NUMBER DESCRIPTION
3D32XK-200 MicroDisplay with CAN, I/O
3D32HK-200 MicroDisplay with CAN, I/O and heater
3D32XKR-200 MicroDisplay with CAN
3D32HKR-200 MicroDisplay with CAN and heater
3D32CABLE-1 MicroDisplay Programming Cable
with Power Supply
REAR CONNECTOR
0 Function
1 V in Positive
2 V Return
3 RS-485 +
4 RS-485 -
5 Digital in 1
6 Digital in 2
7 Digital in 3
8 Digital out 1
9 Digital out 2
10 CAN shield
11 CAN HI
12 CAN LOW
Mating Connector: DEUTSCH DT06-12SA
MOUNTING INFO
Use M6 Nut (1mm pitch)
Max Torque 25 in-lbs
CE COMPLIANCE
EMC EN 13309:2010 ESA
www.grayhill.com
www.grayhill.com