Operation Manual
24
NiCd conditioning program
Ni-Cd manual program
Ni-Cd discharge program
________________
________________NiCd manual
C:2.5A
DEC
INC
+
-
Select this program when you simply wish to recharge a
battery using the set charge current.
You can adjust the charge current using the INC / DEC
buttons, but only before you connect the pack for
charging. The range available is 0.1 A to 8 A.
The charge process is terminated automatically in
accordance with the values already set for „Ni-Cd Delta
Peak cut-off voltage“.
The typical purpose of this program is to determine the
residual capacity of a transmitter, receiver or drive
battery, or to discharge the pack to a defined level.
In this program the charger discharges the pack using the
set discharge current (0.10 ... 5.00 A, left of screen) until
its voltage falls to the set final discharge voltage (0.1 ...
16.8 V, right of screen).The set final discharge voltage
should be a value of around 0.9 ... 1,1 V per cell, in order
to avoid the pack becoming deep-discharged. Deep-
discharging a pack runs the risk of reversing individual
cells, i.e. they exhibit reversed polarity.
________________
________________NiCd discharge
1.00A 4.8V
DEC
INC
+
-
DEC
+
-
ENTER
INC
Ni-Cd automatic program
________________
________________NiCd automatic
C:2.5A limited
DECINC
+
-
In this program the charger detects the type of Ni-Cd
battery connected to it, and adjusts the charge current
accordingly to avoid overcharging the pack.
The maximum charge current can be set before you
connect the battery to be charged. This is done using the
INC / DEC buttons; the range available is 0.1 A to 8 A, or
no restriction. The charge process is terminated auto-
matically in accordance with the values already set for
„Ni-Cd Delta Peak cut-off voltage“.
INC
This program is designed to optimise the capacity of a
battery, and balance the state of its component cells.At
top right you can set use the INC or DEC buttons to
determine whether the conditioning program is to start
with a charge or discharge cycle. After this you set the
number of cycles from 1 to 5 (e.g., if you set three cycles,
the pack will be charged and discharged three times). The
program discharges the battery using the set discharge
current stated on the right of the screen (0.10 ... 5.00 A),
and then recharges it using the charge current (0.1 ...
8.0 A) shown on the left of the screen. The charge
process is terminated automatically in accordance with
the values already set for „Ni-Cd Delta Peak cut-off
voltage“. The method of reading out the values for the
individual cycles is described in the section „Screen
displays“.
________________
________________NiCd cycle C>D 1
C:2.5A E:1.00A
DEC
INC
+
-
DEC
INC
+
-
ENTER
DEC
DEC
INC
or
ENTER