Operation Manual

31
11. Ni-Cd programs
A set of convenient charge programs for recharging Nickel-Cadmium batteries, as commonly
used for modelling purposes. When the charge/balancing program is finished, the screen
displays the name of the charge program alternating with the message „END“, together with the
(charge) time, the last charge current, the charged-in capacity and the battery voltage, and
continues to do so until you disconnect the battery. This information can often give you a useful
indication about the Ni-Cd pack’s charge characteristics and capacity, or warn you if the charger
has incorrectly assessed the pack as being „full“.
Ni-Cd manual program
________________
________________NiCd manual
C:2.5A
DEC
INC
+
-
Select this program when you simply wish to recharge a
battery using the set charge current.
You can adjust the charge current using the INC / DEC
buttons, but only before you connect the pack for
charging. The range available is 0.1 A to 5 A.
The charge process is terminated automatically in
accordance with the values already set for „Ni-Cd Delta
Peak cut-off voltage“.
Ni-Cd automatic program
________________
________________NiCd automatic
C:2.5A limited
DECINC
+
-
In this program the charger detects the type of Ni-Cd
battery connected to it, and adjusts the charge current
accordingly to avoid overcharging the pack.
The maximum charge current can be set before you
connect the battery to be charged. This is done using the
INC / DEC buttons; the range available is 0.1 A to 5 A, or
no restriction. The charge process is terminated auto-
matically in accordance with the values already set for
„Ni-Cd Delta Peak cut-off voltage“.
NiCd
AUTOMATIC-
program
NiCd
MANUAL-
program
NiCd
delta-peak
trigger voltage
MODE MODE MODE MODE
NiCd
balancing
program