Operation Manual
Page 18/53
1. MEMORY AND BATTERY SETUP MENU SCREEN
1-1. Memory selection
- Pressing the dial in Memory[00] then rotate the dial to select the wanted memory.
- Memory 0, 1-50 can be selected.
In any outputs, 0, 1-50 Memory can be selected, but memory room which is
selected by counter output can not be selected.
- “0” Memory automatic mode can be selected at the same time in either channel 1
or channel 2.
The datas of Memory [0] are not stored into the data memory. Only the
battery type is stored.
In Automatic mode, main screens will be only shown as like order -
MEMORY Æ CHARGE Æ DISCHARGE Æ DATA VIEW Æ CONFIG
1-2. Battery selection
- In memory screen, select the memory and press “-> button”
- Set your wanted battery, cell or voltage, and capacity.
If battery type is changed, all setting parameters should be initialized, and TRACE
DAT in DAT VIEW mode is clear.
- Input the purchasing date of your battery (day/month/year)
If battery type is changed, the purchasing date on your battery should be
automatically changed to present date.
- In “0” memory, if battery type is changed then press the dial, it should move
“CHARGE SETUP”.
1-3. Battery Name Setting
- You can name your battery pack using up to total 16 letters.
1-4. Auto settings on parameters
- When battery type is changed
It should be clear to battery initial values.
- max. current:
The max. Charge or discharge current should be changed to 1C rate.
Safety timer value is automatically changed.
However, battery type and max. charge current MUST be set correctly.