User manual

24 / 28
S5012_Alpha_110_jh_V1
Finally complete the procedure for yaw: on the transmitter, briefly
set the yaw command fully to the right. Turn the copter so that
the nose turns more than 45 degrees to the right; the axis is dis-
played, the field is no longer highlighted and identification of this
axis is complete.
The gyros and operating directions have now been assigned.
Now check to make sure that the operating directions are cor-
rect.
To do this remove the propeller of the copters and give
approximately a quarter throttle, all motors are running at
the same speed.
Tilt the Copter in Attitude mode so that its nose is facing
downwards
the front motors must turn faster than back
ones. Tilt the Copter in Attitude mode to one side
the
motors of the side, in witch you tilt the model, must turn
faster then the motors on the other side.
Roll and Nick setting
For Attitude and Rate mode:
ROLL/NICK P
Set this parameter in steps of 5 higher and higher, until a medi-
um-speed overshoot occurs. Then go some steps back in order
to prevent the soar up climb in case of full throttle.
ROLL/NICK D
Now adjust well to the D component in steps of 5, until the Cop-
ter engages exactly on nick and roll. A too high value leads to
very rapid oscillations.
DAMPING
The damping factor should be set as low as possible, but as
high as necessary, so that the PID control can operate optimally
and the setting can be increased at best. If you do not get vibra-
tions away with the PID settings , then change the damping of
1 step and test whether the setting works better or worse. Rec-
ommended settings:
ROLL FACTOR %
Set the Roll setting as percent value of the overall gain. For sym-
metric Copters the value can be 100. If, because of its center of
gravity, the Copter is more agile on the Roll axis than on the Nick
axis, then you can change here the roll factor.
Multicopter RO/NI< >
>ROLL/NICK P 40
ROLL/NICK D 30
DAMPING 2
ROLL FACTOR % 100
POWER2SENS. 80
--ATTITUDE MODE--
ROLL/NICK I 40
AGILITY 3
Multicopter RO/NI< >
--RATE MODE--
R/N RATE I 20
RATE 6
Step 4
Optional setting for Roll and Nick