User manual
In the basic transmitter display, use a fi nger or the
provided stylus to touch the gear icon labelled "B":
000 000
000
000
mz
000%
000%
000
000
BATT TIME 00: 01: 23
Graubele
M 1
0:01:23
NORMAL
000:00.0
000:00.0
4.1V
RX TX
RX 00.0V
Touch
The display switches to the green base menu. Touch
the menu item "Rev/Slow" with a fi nger or the provided
stylus.
BACK
SYSTEM
BASE
FUNCTION
Model Sel
E.P.A
Model Type
Rev/Slow
Sub-Trim
Motor
Timer
TX ctl
Fail Safe
Trim Step
Servo
Out.Swap
CH Set
Touch
Servo direction of rotation and control delay
BACK
NORMAL
Graubele
S
1.
2.
3.
4.
5.
.6
NOR
NOR
NOR
NOR
NOR
NOR
7.
8.
9.
10.
11.
12.
INC
RES
DEC
0.0s
0.0s
0.0s
0.0s
0.0s
0.0s
NOR
NOR
NOR
NOR
NOR
0.0s
0.0s
0.0s
0.0s
0.0s
0.0s
NOR
In this display, exclusively the direction of rotation
relating to the respective servo is set in the left column.
In contrast, a delay is entered in the right column for the
control function corresponding to the selected channel.
Reverse/Slow
Setting the servo rotational direction and delay
Note:
•
In contrast to the display of the 12-channel
mz-24 HoTT transmitter in this section,
only channels 1 … 9 are offered in the
display of the 9-channel mz-18 HoTT transmitter.
• If you have created Quick Links in the submenu
"Q.Link" (page 132 or 168) and have assigned an
appropriate name, it appears at the top right such as
"NORMAL" as shown.
However, the settings in the left column,
"direction of servo rotation", have a global
effect. Only the delays may be set for the
specifi c Quick Links in the right column, "Delay".
When setting the delays, activate the wanted Quick
Link by operating its corresponding switch.
• Setting the rotational direction of the servos is
independent of the Quick Link
Important:
The numbers for the servos refer to to the
servos connected to the corresponding
receiver outputs providing that the
transmitter and receiver outputs have not been
swapped. A change in the control mode therefore
does not infl uence the numbering of the servos.
With this option, the direction of servo rotation is
adapted to the specifi cs in the particular model
independent of the Quick Link so that, when the
control linkages and articulations are installed, the
servo's rotational direction does not have to be
considered.
The servo's rotational direction should be
determined before the servo travel is set.
The direction of travel is reversed by touch-
ing the corresponding value fi elds labelled NOR
and REV , such as:
BACK
NORMAL
Graubele
S
1.
2.
3.
4.
5.
.6
NOR
REV
NOR
NOR
REV
NOR
7.
8.
9.
10.
11.
12.
INC
RES
DEC
0.0s
0.0s
0.0s
0.0s
0.0s
0.0s
NOR
NOR
NOR
NOR
NOR
0.0s
0.0s
0.0s
0.0s
0.0s
0.0s
NOR
Note:
As of fi rmware version V1.020, a warning
was inserted which appears when an
attempt is made to change the direction of
travel of CH1:
BACK
NORMAL
Graubele
S
1.
2.
3.
4.
5.
.6
NOR
REV
NOR
NOR
REV
NOR
7.
8.
9.
10.
11.
12.
INC
RES
DEC
0.0s
0.0s
0.0s
0.0s
0.0s
0.0s
NOR
NOR
NOR
NOR
NOR
0.0s
0.0s
0.0s
0.0s
0.0s
0.0s
NOR
YES
NO
Are you sure?
Warning
Touch
Touch NO with a fi nger or the provided stylus to
terminate the procedure. Touch YES to confi rm the
procedure which changes the direction of travel of
the servo connected to CH1.
68
Basic menu - Servo reverse/servo delay